Comparison of chest computed tomography in Turbo FLASH mode with conventional mode for coronary artery disease screening: radiation dose, image quality, and calcium scoring performance.

Ying-Lan Shu, Han Yu, Da-Jing Guo, Ya-Ping Huang, Wen-Li Jiang, Yin-Deng Luo, Jie Xu

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ying-Lan Shu *Department of Radiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.ORCID https://orcid.org/0009-0007-1572-0800
Han Yu *Department of Radiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.ORCID https://orcid.org/0009-0007-9627-5939
Da-Jing GuoDepartment of Radiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.ORCID https://orcid.org/0000-0001-8655-6621
Ya-Ping HuangDepartment of Radiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.ORCID https://orcid.org/0009-0007-3079-9967
Wen-Li JiangDepartment of Radiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.ORCID https://orcid.org/0009-0002-5102-5972
Yin-Deng Luo *Department of Radiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.ORCID https://orcid.org/0000-0001-8720-8418
Jie Xu *Department of Radiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.ORCID https://orcid.org/0000-0002-2523-7915

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Currently, the traditional chest computed tomography (CT) scan mode presents certain limitations in evaluating the coronary artery calcification score (CACS). Therefore, this study aimed to investigate the impact of using the Turbo FLASH mode to optimize chest CT on radiation dose, image quality, and CACS. Methods: In this cross-sectional study, a total of 968 patients who simultaneously underwent routine chest CT (using the Turbo FLASH mode or the conventional mode) and cardiac CT [coronary calcium scan (CCS) and coronary CT angiography] were retrospectively collected. A comparative analysis was performed between the FLASH mode (n=493) and the conventional mode (n=475) in terms of radiation dose and image quality. CACS analysis was carried out using a semi-automatic software based on CCS, chest CT (FLASH), and chest CT (conventional). Using the CCS-CACS as a reference, the correlation, consistency, and concordance rate of risk categories based on CACS from the two chest CT modes were independently calculated. Results: Chest CT (FLASH) reduced the mean radiation dose by 36.47 mGy·cm (11.1%) and exhibited fewer motion artifacts, albeit with a worse signal-to-noise ratio (SNR) (all P<0.05). For CACS quantification, chest CT (FLASH) showed a stronger linear correlation (r, 0.998 Conclusions: The Turbo FLASH mode of chest CT excels in detecting microcalcifications, reducing false negatives, and improving the accuracy of risk categories. It also lowers radiation exposure, but it may compromise the SNR of images.

Indexed as

cardiovascular risk scoreCoronary artery disease (CAD)coronary calcium scan (CCS)radiation dosevascular calcification

Identifiers

PMID40160616
PMCPMC11948383