Evidence map›Paper›PMID 40160129›Full record

ArticleInternational journal for numerical methods in biomedical engineering2025

Hemodynamics in Cerebral Aneurysms and Parent Arteries With Incompletely Expanded Flow Diverter Stents.

Soichiro Fujimura, Kazuya Yuzawa, Katharina Otani, Kostadin Karagiozov, Hiroyuki Takao, Toshihiro Ishibashi, Koji Fukudome, Makoto Yamamoto, Yuichi Murayama

Abstract read
In one paragraph

Article in International journal for numerical methods in biomedical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Soichiro FujimuraDepartment of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan.ORCID https://orcid.org/0000-0002-4651-8249
Kazuya YuzawaDivision of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan.
Katharina OtaniDepartment of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan.ORCID https://orcid.org/0000-0002-2322-3405
Kostadin KaragiozovDepartment of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan.ORCID https://orcid.org/0000-0001-6105-0480
Hiroyuki TakaoDivision of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan.ORCID https://orcid.org/0000-0002-9285-9642
Toshihiro IshibashiDepartment of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan.ORCID https://orcid.org/0000-0003-1044-5604
Koji FukudomeDepartment of Mechanical Engineering, Kanazawa Institute of Technology, Nonoichi, Ishikawa, Japan.ORCID https://orcid.org/0000-0003-1080-6916
Makoto YamamotoDepartment of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan.ORCID https://orcid.org/0000-0001-7844-331X
Yuichi MurayamaDepartment of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan.ORCID https://orcid.org/0000-0003-3490-385X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Braided stents for cerebral aneurysms, including flow diverter stent (FDS), may exhibit incomplete stent expansion (IncompSE) during deployment, depending on factors related to the parent artery. Poor stent apposition due to IncompSE can increase the risk of complications or incomplete aneurysm occlusion. Since hemodynamics may play a critical role in these adverse events, we investigated hemodynamic parameters associated with IncompSE using computational fluid dynamics (CFD) analysis. Three basic geometries were generated to represent an aneurysm located on the siphon of the internal carotid artery. CFD analysis was conducted for each geometry under a total of 12 patterns, including before deployment, complete stent expansion (CompSE), and IncompSE on the distal and proximal sides. We focused on hemodynamic parameters reported to influence occlusion or complications after FDS deployment. The change rate (CR) of these parameters was calculated by comparing conditions before and after FDS deployment. In the cases of CompSE, volume flow (VF) into the aneurysm and maximum wall shear stress (WSS) on the aneurysmal wall decreased on average by 52.7% and 34.7%, respectively. Conversely, in the cases of IncompSE, higher VF, inflow jets, and vortices were observed within the aneurysm. Increased WSS at the aneurysmal neck and parent artery was also noted. While static pressure on the aneurysmal wall and energy loss through the aneurysm region showed minimal change in the case of CompSE, both parameters increased in cases of IncompSE. These findings suggest that IncompSE may result in hemodynamic conditions that are suboptimal for treatment. IncompSE of FDS can potentially induce unfavorable hemodynamic changes, including increased blood flow into the aneurysm and elevated pressure on the aneurysmal wall compared to pre-deployment conditions.

Indexed as

HemodynamicsIntracranial AneurysmStentsHumansHydrodynamicsModels, CardiovascularStress, Mechanical

Identifiers

PMID40160129
PMCPMC11955936

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.