Activated Clotting Time Requires Adaptation Across Altered Measurement Devices: Determination of Appropriate Range During Atrial Fibrillation Ablation.

Haruna Sakanoue, Hirosuke Yamaji, Sayaka Okamoto, Kumi Okano, Yuka Fujita, Shunichi Higashiya, Takashi Murakami, Satoshi Hirohata, Shozo Kusachi

Abstract read
In one paragraph

Article in Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Haruna SakanoueDepartment of Nursing, Okayama Heart Clinic, Okayama, Japan.
Hirosuke YamajiHeart Rhythm Center, Okayama Heart Clinic, Okayama, Japan.ORCID 0000-0002-7758-154X
Sayaka OkamotoDepartment of Nursing, Okayama Heart Clinic, Okayama, Japan.
Kumi OkanoDepartment of Nursing, Okayama Heart Clinic, Okayama, Japan.
Yuka FujitaDepartment of Nursing, Okayama Heart Clinic, Okayama, Japan.
Shunichi HigashiyaHeart Rhythm Center, Okayama Heart Clinic, Okayama, Japan.
Takashi MurakamiHeart Rhythm Center, Okayama Heart Clinic, Okayama, Japan.
Satoshi HirohataDepartment of Medical Technology, Okayama University Graduate School of Health Sciences, Okayama, Japan.
Shozo KusachiHeart Rhythm Center, Okayama Heart Clinic, Okayama, Japan.ORCID 0000-0002-9531-076X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BackgroundMethods for measuring activated clotting time (ACT) are not yet standardized.ObjectivesTo adjust and compare values between two measurement systems and to optimize ACT during atrial fibrillation (AF) ablation.MethodsTwo systems were compared: electromagnetic detection using a rotating tube (EM system; Hemochron Response) and photo-optical detection using a cartridge immersed in blood (PO system; ACT CA-300TM).ResultsACT was measured simultaneously in 124 instances in 53 patients before and during AF ablations using both methods. A linear regression analysis showed ACT (EM system) = 1.19 × ACT (PO system) + 9.03 (p < .001, r = 0.90). Bland-Altman plots indicated an average difference of 50 s between the two systems. In 3364 ACT measurements from 1161 ablations, the EM system recorded a mean ACT of 320 ± 44 s (range 156-487 s). Estimating the target range as mean ± 1 SD range, the EM system's range was 275-365 s, in 5-s increments. The pre-ablation ACT measured on the EM system was 143 ± 28 s (115-170 s). Cardiac tamponade occurred in 4 out of 2085 ablations (0.19%) over 5 years, with ACT values ranging from 330 to 391 s on the EM system. Based on these findings, the estimated optimal ACT range for the PO system was adjusted to 225-300 s to align with the EM system's range of 275-365 s.ConclusionsACT target ranges should be system-specific, and direct extrapolation between devices is not recommended. Adjustment is clinically necessary when switching systems.

Indexed as

Atrial FibrillationCatheter AblationAgedFemaleHumansMaleMiddle AgedWhole Blood Coagulation Timeanticoagulationcatheterheparinpoint-of-care testingsupraventricular arrhythmia

Identifiers

PMID40156227
PMCPMC11954560

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.