ArticleJournal of fluorescence2025
Sensitive and Facile Detection of Vitamin D Based on Fluorescent Labeled Aptamer Probe and Exonuclease I-Assisted Signal Amplification.
Article in Journal of fluorescence, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
This study presents a rapid, simple aptamer-based fluorescence sensor using fullerenes as a quencher for detecting vitamin D3. Fullerenes, with its π-electron cloud, acts as a powerful electron acceptor, facilitating Förster resonance energy transfer (FRET) from carboxyfluorescein (FAM). The aptamer, labeled with 5'6-FAM, adsorbs onto the fullerenes surface through hydrogen bonding and π-π stacking interactions, leading to fluorescence quenching. Upon vitamin D3 binding, the aptamer forms a hairpin structure that prevents adsorption onto the fullerenes surface, restoring fluorescence. The fullerenes were characterized using UV-Vis, FT-IR, Raman spectroscopy, SEM, TEM, and zeta potential measurements. The sensor's response to varying vitamin D3 concentrations was analyzed with a fluorescence spectrometer, revealing a linear detection range of 0-600 nM and a detection limit of 200 nM, which improved to 50 nM with exonuclease I. The sensor demonstrated a recovery rate of 88.4%-96.3% for vitamin D3 in water samples, confirming its feasibility for practical applications. In addition, our proposed sensor exhibited good repeatability (3.27%) and stability (90%). The innovative use of fullerenes as a fluorescence quencher, along with the aptamer's specific binding to vitamin D3, provides a novel and highly sensitive avenue for vitamin D3 detection.
Indexed as
Identifiers
40153233What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.