Evidence map›Paper›PMID 40153195›Full record

ArticleAnnals of biomedical engineering2025

Field-Ready Suction Solutions for Emergencies: The Battlefield Ready Innovative Suction Kit (BRISK).

Saketh R Peri, Maria J Londono, Rakib Hasan, Connor J Evans, Robert A De Lorenzo, R Lyle Hood

Erratum issuedAbstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Saketh R PeriDepartment of Biomedical Engineering, University of Texas at San Antonio, San Antonio, TX, USA.ORCID http://orcid.org/0000-0001-9115-2429
Maria J LondonoDepartment of Biomedical Engineering, University of Texas at San Antonio, San Antonio, TX, USA.ORCID http://orcid.org/0009-0006-6962-3988
Rakib HasanDepartment of Mechanical Engineering, University of Texas at San Antonio, San Antonio, TX, USA.ORCID http://orcid.org/0000-0001-6728-6638
Connor J EvansEmergency Medicine Department, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA.ORCID http://orcid.org/0000-0002-4181-7282
Robert A De LorenzoDepartment of Biomedical Engineering, University of Texas at San Antonio, San Antonio, TX, USA.ORCID http://orcid.org/0000-0003-4364-9590
R Lyle HoodDepartment of Biomedical Engineering, University of Texas at San Antonio, San Antonio, TX, USA. Lyle.hood@utsa.edu.ORCID http://orcid.org/0000-0003-0478-2065

Funding

National Science Foundation 2245173
6 · The paper itself

Abstract

introductionPortable suction devices are crucial for emergency airway management. Commercially-available units are unsuitable for field use due to size and power needs. A light-weight and multi-orientation operable portable suction device, Battlefield Ready Innovative Suction Kit (BRISK) was developed. The design was informed by feedback from combat medics, paramedics, and EMTs.

methodsEnd-user engagement and feedback defined BRISK's design. The fabricated prototype used a vacuum pump and hydrophobic syringe filters. Performance tests measured vacuum pressure, air and liquid (water and ISO vomit simulant) flow rates, volume of water suctioned in different orientations (upright, tilted, or inverted), and contamination prevention between BRISK, SSCOR Quickdraw, and Laerdal LCSU4.

resultsThe BRISK device-weighing 0.97 kg-demonstrated a maximum vacuum pressure of 570 ± 6 mmHg and an air flowrate of 5.20 L/min. Liquid flow rates (L/min) for BRISK, LCSU4, and SSCOR with water were 4.92 ± 0.2, 6.97 ± 0.1, and 5.37 ± 0.1, respectively. With ISO vomit simulant, the rates were 3.23 ± 0.2, 3.06 ± 0.4, and 2.23 ± 0.1. BRISK showed consistent performance across orientations (p = 0.081), while LCSU4 and SSCOR varied significantly (p < 0.0001). The BRISK's cross-contamination between filters and the pump was 0.01%, which is far less than the  rated contamination level of 0.1% as described by ISO 10079-1.

conclusionBRISK is 30% lighter and achieves competitive vacuum pressures and liquid flow rates than comparable units currently in the market. It ensures effective evacuation of liquids in all orientations: upright, tilted, or inverted. These results demonstrate the BRISK has the potential to provide superior clinical performance in pre-hospital and first response scenarios.

Indexed as

Equipment DesignSuctionVacuumAirway managementAirway obstructionCombat medicEmergency traumaPortable suction devicePre-hospital

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked