Evidence map›Paper›PMID 40153056›Full record

ArticleClinical oral investigations2025

Clinical application of customized total temporomandibular joint prosthesis by 3D printing: a five-year follow-up study.

Qingyu Xu, Liang Huo, Xiang Wei, Zixian Jiao, Zixiang Han, Lingtong Bu, Minjie Chen, Jisi Zheng, Chi Yang

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical oral investigations, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Qingyu Xu *Department of Oral Surgery, Shanghai Ninth People's Hospital, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, No. 639 Zhi Zao Ju Rd., Shanghai, 200011, China.
Liang Huo *Department of Oral Surgery, Shanghai Ninth People's Hospital, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, No. 639 Zhi Zao Ju Rd., Shanghai, 200011, China.
Xiang WeiDepartment of Oral Surgery, Shanghai Ninth People's Hospital, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, No. 639 Zhi Zao Ju Rd., Shanghai, 200011, China.
Zixian JiaoDepartment of Oral Surgery, Shanghai Ninth People's Hospital, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, No. 639 Zhi Zao Ju Rd., Shanghai, 200011, China.
Zixiang HanDepartment of Oral Surgery, Shanghai Ninth People's Hospital, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, No. 639 Zhi Zao Ju Rd., Shanghai, 200011, China.
Lingtong BuDepartment of Oral Surgery, Shanghai Ninth People's Hospital, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, No. 639 Zhi Zao Ju Rd., Shanghai, 200011, China.
Minjie ChenDepartment of Oral Surgery, Shanghai Ninth People's Hospital, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, No. 639 Zhi Zao Ju Rd., Shanghai, 200011, China. chenminjie00@126.com.
Jisi ZhengDepartment of Oral Surgery, Shanghai Ninth People's Hospital, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, No. 639 Zhi Zao Ju Rd., Shanghai, 200011, China. 237111641@qq.com.
Chi YangDepartment of Oral Surgery, Shanghai Ninth People's Hospital, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, No. 639 Zhi Zao Ju Rd., Shanghai, 200011, China. yang_chi63@163.com.

Funding

National Key R&D Program of China 2023YFC2509100Natural Science Foundation of China 82370984Science and Technology Commission of Shanghai Municipality 22S31903400Science and Technology Commission of Shanghai Municipality 23Y31900400Shanghai Jiao Tong University School of Medicine Affiliated Ninth People's Hospital 2022hbyjxys-zjs
6 · The paper itself

Abstract

objectivesThis study aims to evaluate the clinical efficacy and stability of customized total temporomandibular joint (TMJ) prosthesis by 3D printing from TMJ Yang's prosthesis system after five-years follow-up. MATERIALS AND

methodsThis prospective single-center case series study recruited patients required total TMJ prosthesis replacement from March 2016 to September 2022. Patient information was collected and followed up at 1 month, 3 months, 6 months, 1 year, 2 years and 5 years post-surgery. Using CT and panoramic scans to evaluate the prosthesis' position and bone integration. Pain, diet and mandibular function were evaluated by VAS score, and maximum interincisal opening, mouth opening deviation and mandibular maximum forward and lateral movement were recorded. Statistical analyses include descriptive statistics for demographic characteristics and paired t-tests and ANOVA for quantitative analysis.

results49 consecutive patients with an average age of 52.88 ± 13.78 years were included. The mean follow-up time was 5.00 ± 1.88 years. There were no postoperative infections, and the wound healed well. Patients' postoperative facial shape and occlusion remained unchanged except for one patient improved the facial shape by second-stage genioplasty. The position of the prosthesis was stable and the bone integration was satisfactory. After surgery, pain, mandibular function, and diet improved significantly (P < 0.05) and remained stable 1 year later. The maximum interincisal opening increased (P < 0.05), with mouth opening deviation and movement on the affected side similar to preoperative levels, but movement on the unaffected side and forward movement decreased slightly.

conclusionsThe customized total TMJ prosthesis by 3D printing from TMJ Yang's prosthesis system is safe, stable and effective during five years' clinical application. CLINICAL RELEVANCE: This study provides a new, safe and effective prosthesis option for temporomandibular joint reconstruction.

Indexed as

Arthroplasty, ReplacementJoint ProsthesisPrinting, Three-DimensionalProsthesis DesignTemporomandibular JointTemporomandibular Joint DisordersAdultFemaleFollow-Up StudiesHumansMaleMiddle AgedProspective StudiesRadiography, PanoramicTomography, X-Ray ComputedTreatment OutcomeClinical applicationCustomized prosthesisTemporomandibular jointTMJ reconstructionTMJ surgery

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.