Evidence map›Paper›PMID 40152453›Full record

ArticleMagnetic resonance in medicine2025

Imaging near titanium total hip arthroplasty at 0.55 T compared with 3 T.

Kübra Keskin, Sophia X Cui, Bochao Li, Jordan S Gross, Jay Acharya, Zorica Buser, Jay R Lieberman, Brian A Hargreaves, Krishna S Nayak

Abstract readComparative Study
In one paragraph

Article in Magnetic resonance in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Imaging Near Spinal Fixation Hardware at 0.55 T Compared With 3 T.Journal of magnetic resonance imaging : JMRI · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Current Uses for Medical Imaging With Orthopaedic Implant Technology.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
    Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Kübra KeskinElectrical and Computer Engineering, University of Southern California, Los Angeles, California, USA.ORCID 0000-0003-4571-2813
Sophia X CuiSiemens Medical Solutions USA, Los Angeles, California, USA.ORCID 0000-0002-5133-4903
Bochao LiBiomedical Engineering, University of Southern California, Los Angeles, California, USA.ORCID 0000-0002-5267-9129
Jordan S GrossDiagnostic Radiology, University of California Los Angeles, Los Angeles, California, USA.
Jay AcharyaDiagnostic Radiology, University of California Los Angeles, Los Angeles, California, USA.
Zorica BuserOrthopedic Surgery, Grossman School of Medicine, New York University, New York, New York, USA.
Jay R LiebermanOrthopedic Surgery, University of Southern California, Los Angeles, California, USA.
Brian A HargreavesRadiology, Stanford University, Stanford, California, USA.ORCID 0000-0003-0982-3508
Krishna S NayakElectrical and Computer Engineering, University of Southern California, Los Angeles, California, USA.ORCID 0000-0001-5735-3550

Funding

Improved Diagnostic MRI around Metallic ImplantsR01AR078912 · NIAMS · UNIVERSITY OF SOUTHERN CALIFORNIA · PI Brian Andrew Hargreaves, Krishna Shrinivas Nayak · 2022 to 2026
$2.4M
National Science Foundation 1828736NIAMS NIH HHS R01 AR078912NIH HHS R01-AR078912
6 · The paper itself

Abstract

purposeTo compare 0.55 T and 3 T MRI for imaging patients with titanium total hip arthroplasty (THA). Patients with orthopedic metallic implants often require diagnostic imaging to evaluate adjacent tissues. MRI performance measures, including artifact levels and SNR, vary with field strength.

methodsSix patients with titanium THA were scanned with similar protocols at 0.55 T and 3 T, including proton density (PD) weighted turbo spin echo (TSE), PD TSE with view-angle tilting (TSE + VAT), PD slice encoding for metal artifact correction (SEMAC), and short tau inversion recovery with SEMAC (STIR-SEMAC). Images from both field strengths were scored by two readers and qualitatively and quantitatively compared.

resultsDiagnostic confidence was significantly higher at 0.55 T compared to 3 T. Perceived metal artifact was substantially reduced at 0.55 T compared to 3 T. At 0.55 T, diagnostic imaging was achieved both without and with multi spectral imaging (MSI) for PD weighted images.

conclusionCompared to 3 T, 0.55 T MRI offers substantially reduced metal artifacts and higher diagnostic confidence when imaging titanium THA. Advanced multi-spectral techniques may not be required when the metallic components are entirely titanium.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisMagnetic Resonance ImagingTitaniumAgedArtifactsFemaleHumansMaleMiddle AgedReproducibility of ResultsSensitivity and SpecificityTitanium0.55 T3 Timaging near orthopedic metallic implantstitaniumtotal hip arthroplasty

Identifiers

PMID40152453
PMCPMC12021306

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.