ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2025
External femoral rotation of 2 degrees is associated with the lowest stuffing rates around the femur in functionally aligned TKA.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Overstuffing of the lateral distal condyle is associated with worse intraoperative patellar tracking and postoperative lateral patellar tilt during robotic-assisted cruciate-retaining total knee arthroplasty.Journal of robotic surgery · 2026Article
- Kinematical-aligning of femoral component decreases overstuffing of lateral distal condyle and provides better patellar tracking and postoperative outcomes in robotic-assisted total knee arthroplasty.Journal of robotic surgery · 2026Article
- External femoral rotation of 2 degrees is associated with the lowest stuffing rates around the femur in functionally aligned TKA.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeModifying femoral morphology after total knee arthroplasty (TKA) poses a potential risk for ligament-imbalances and patella mal-tracking. The purpose of this study was primarily to quantify TKA-induced stuffing around the femur and secondarily assess the effect of femoral rotation (FR) on trochlear and condylar anatomy-changes.
methodsKnee anatomy-modification was quantified in 69 robotic-assisted TKAs utilising tibia-based functional alignment (FA). Caliper-measurements were performed on the medial (Med), central (Ctr), and lateral (Lat) sides of the following resection planes: anterior trochlea (AT), oblique trochlea (OT), distal condyles (DC), posterior condyles (PC) and tibia (TIB). The same caliper-measurements were performed on the femoral components used to calculate bone-implant differences and analyse possible patterns of postoperative trochlear anatomy-modifications (TAM) and condylar anatomy-modifications (CAM). Over- or understuffing analysis for different FRs and regression analysis were conducted to assess the effect of FR on CAM and TAM.
resultsTAM results were Lat-AT -3.2 mm ([95% confidence interval [CI]: -3.71 to -2.63], p < 0.001), Ctr-AT 0.7 mm ([95%CI: 0.22-1.32], p = 0.02), and Ctr-OT -1.7 mm ([95%CI: -1.85 to -0.93], p < 0.001) with stuffing > 2 mm in 60.9%, 39.1%, and 39.1%, respectively. CAM results were Med-DC -3.6 mm ([95%CI: -4.14 to -3.05], p < 0.001) and Lat-PC 3.0 mm ([95%CI: 2.48-3.38], p > 0.001) with stuffing > 2 mm in 78.3% and 63.8%. FR (3.8 ± 2.6°, range: -1.6° to 8.5°) affected mostly the anterior (r = -0.40, p < 0.001) and posterior (r = 0.71, p < 0.001) aspects of the knee but hardly the OT plane (r = 0.06, p = 0.624) and the trochlear groove to its full range of flexion (r = 0.21, p = 0.17). External FR 2° was associated with the lowest incidence of femoral stuffing > 2 mm and ≥ 4 mm.
conclusionsFA-typical modification-pattern was a TAM with lateral facet understuffing, and CAM with medial distal understuffing and lateral posterior overstuffing. Trochlear groove height was non-significantly affected by FR. FA with the current off-the-shelf implant induces the lowest stuffing rates when set in 2° external femoral rotation. LEVEL OF EVIDENCE: Level II.
Indexed as