Evidence map›Paper›PMID 40150701›Full record

ArticleBioengineering (Basel, Switzerland)2025

Increased VA-ECMO Pump Speed Reduces Left Atrial Pressure: Insights from a Novel Biventricular Heart Model.

Anirudhan Kasavaraj, Christian Said, Laurence Antony Boss, Gabriel Matus Vazquez, Michael Stevens, Jacky Jiang, Audrey Adji, Christopher Hayward, Pankaj Jain

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Anirudhan KasavarajFaculty of Medicine, UNSW Sydney, Kensington 2052, Australia.
Christian SaidFaculty of Medicine, UNSW Sydney, Kensington 2052, Australia.
Laurence Antony BossFaculty of Medicine, UNSW Sydney, Kensington 2052, Australia.ORCID 0000-0003-1587-4598
Gabriel Matus VazquezFaculty of Medicine, UNSW Sydney, Kensington 2052, Australia.
Michael StevensFaculty of Engineering, UNSW Sydney, Kensington 2052, Australia.ORCID 0000-0003-3583-688X
Jacky JiangFaculty of Medicine, UNSW Sydney, Kensington 2052, Australia.ORCID 0000-0003-3061-2940
Audrey AdjiFaculty of Medicine, UNSW Sydney, Kensington 2052, Australia.
Christopher HaywardFaculty of Medicine, UNSW Sydney, Kensington 2052, Australia.
Pankaj JainFaculty of Medicine, UNSW Sydney, Kensington 2052, Australia.ORCID 0000-0002-4867-1773

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

aimsThe effect of veno-arterial extracorporeal membrane oxygenation (VA-ECMO) on left atrial pressure (LAP) in the presence of interventricular interaction and the Frank-Starling mechanism is unknown. We developed and validated a mock circulatory loop (MCL) incorporating a novel, 3D-printed biventricular heart model and Frank-Starling algorithm, and used this model to assess the determinants of LAP during VA-ECMO support.

methodsThe MCL was designed to allow a separate ventricle or biventricular configuration, with or without an active Frank-Starling mechanism. The biventricular model with Frank-Starling mechanism was validated in terms of (1) the presence and degree of ventricular interactions; (2) its ability to simulate Frank-Starling physiology; and (3) its capacity to simulate normal and pathological cardiac states. In the separate ventricle and biventricular with Frank-Starling models, we assessed the effect on LAP of changes in mean aortic pressure (mAoP), ECMO pump speed, LV contractility and ECMO return flow direction.

resultsIn the biventricular configuration, clamping RA inflow decreased RAP, with a concurrent decrease in LAP, consistent with direct ventricular interaction. With a programmed Frank-Starling mechanism, decreasing RAP was associated with a significant reduction in both LV outflow and LV end-systolic pressure. In the biventricular model with a Frank-Starling algorithm, the MCL was able to reproduce pre-defined normal and pathological cardiac output, and arterial and ventricular pressures. Increasing aortic pressure caused a linear increase in LAP in the separate ventricle model, which was attenuated in the biventricular model with Frank-Starling mechanism. Increasing ECMO pump speed caused no change in LAP in the separate ventricle model (

conclusionsInterventricular interactions and the Frank-Starling mechanism can be simulated in a physical, biventricular MCL. In their presence, the effects of VA-ECMO on LAP are mitigated, with LAP reduction and stabilization at maximal VA-ECMO speeds.

Indexed as

cardiogenic shockextracorporeal membrane oxygenationheart failurehemodynamicsmechanical circulatory supportphysiology

Identifiers

PMID40150701
PMCPMC11939398

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.