ArticleBioengineering (Basel, Switzerland)2025
Sensitivity of Lumbar Total Joint Replacement Contact Stresses Under Misalignment Conditions-Finite Element Analysis of a Spine Wear Simulator.
Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Effect of Axial and Coronal Malalignment on Polyethylene Stresses in Lumbosacral Total Joint Replacement: A Finite Element Study.Bioengineering (Basel, Switzerland) · 2026Article
- The Effect of High-Demand Loading Conditions on Polyethylene Stresses in Total Joint Replacement of the Lumbar Spine at L5-S1.Annals of biomedical engineering · 2026Article
- Total joint replacement of the lumbar spine: surgical technique and procedural details.Journal of spine surgery (Hong Kong) · 2026Article
- Polyethylene Stresses in Lumbar Total Joint Replacement Under Elevated Loading: Insights from an Anatomic Finite Element Model.Bioengineering (Basel, Switzerland) · 2026Article
- Sensitivity of Lumbar Total Joint Replacement to Axial and Coronal Plane Misalignment Using Computational Modeling.International journal of spine surgery · 2025Article
- Biomechanical Analysis of Rheumatoid Arthritis of the Hand and the Design of Orthotics: A Finite Element Study.Bioengineering (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
A novel total joint replacement (TJR) that treats lumbar spine degeneration was previously assessed under Mode I and Mode IV conditions. In this study, we relied on these previous wear tests to establish a relationship between finite element model (FEM)-based bearing stresses and in vitro wear penetration maps. Our modeling effort addressed the following question of interest: Under reasonably worst-case misaligned conditions, do the lumbar total joint replacement (L-TJR) polyethylene stresses and strains remain below values associated with Mode IV impingement wear tests? The FEM was first formally verified and validated using the risk-informed credibility assessment framework established by ASME V&V 40 and FDA guidance. Then, based on criteria for unreasonable misuse outlined in the surgical technique guide, a parametric analysis of reasonably worst-case misalignment using the validated L-TJR FEM was performed. Reasonable misalignment was created by altering device positioning from the baseline condition in three scenarios: Axial Plane Convergence (20-40°), Axial Plane A-P Offset (0-4 mm), and Coronal Plane Tilt (±20°). We found that, for the scenarios considered, the contact pressures, von Mises stresses, and effective strains of the L-TJR-bearing surfaces remained consistent with Mode I (clean) conditions. Specifically, the mechanical response values fell below those determined under Mode IV (worst-case) boundary conditions, which provided the upper-bound benchmarks for the study (peak contact pressure 83.3 MPa, peak von Mises stress 32.2 MPa, and peak effective strain 42%). The L-TJR was judged to be insensitive to axial and coronal misalignment under the in vitro boundary conditions imposed by the study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.