Evidence map›Paper›PMID 40148896›Full record

ArticleJournal of orthopaedic surgery and research2025

A novel external fixation for treating tibial fractures: a finite element and biomechanical study.

Shen Liu, Xiangdang Liang, Songyang Liu, Zhanshe Guo, Xing Wei, Yonghui Liang

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Shen LiuDepartment of Orthopaedics, Aerospace Center Hospital, Beijing, China.
Xiangdang LiangDepartment of Orthopedics, General Hospital of People's Liberation Army, Beijing, China. lxd301@263.net.
Songyang LiuDepartment of Orthopaedics, Aerospace Center Hospital, Beijing, China.
Zhanshe GuoSchool of Instrumentation Science and Opto-electronics Engineering, Beihang University, Beijing, China.
Xing WeiDepartment of Orthopaedics, Aerospace Center Hospital, Beijing, China.
Yonghui LiangDepartment of Emergency, Aerospace Center Hospital, 15 Yuquan Road, Haidian District, Beijing, 100049, China. 13910199041@163.com.

Funding

China Healthy Longevity Catalyst Awards 2023-JKCS-26Science Foundation of AMHT 2022YK23
6 · The paper itself

Abstract

objectiveDesign a new type of external fixation device that is small in size, high in strength, and capable of achieving the mechanical requirements for fracture healing. Verify the rationality and effectiveness of the device in treating tibial fractures through finite element analysis and biomechanical comparative tests.

methodsFinite element simulation was performed on the new external fixation device to treat fractures, to verify whether the mechanical properties of the device meet the requirements of fracture healing. A fracture gap model was created using Sawbones to simulate midshaft tibial comminuted fractures. The experiment was divided into four groups, testing the mechanical characteristics of the new external fixation (NEF), locking compression plate (LCP), the unilateral external fixation (UEF), and the externalized locking compression plate (E-LCP). The axial compression, torsion, fatigue and ultimate load tests were performed separately. Data were collected and statistical analysis was performed to verify whether there were statistical differences between the four groups.

resultsThe finite element analysis of NEF demonstrated that the fracture end was displaced by 0.512 mm under 700 N loading, and the maximum stress value of the device was 189 MPa, which met the mechanical requirements. Axial compression tests showed that LCP (2108.596 N/mm) had the highest stiffness, and NEF (519.489 N/mm) had higher stiffness than both UEF (327.153 N/mm) and E-LCP (316.763 N/mm) (p < 0.05), but no significant difference between UEF and E-LCP (p = 0.313). There was a significant difference in mean torsional stiffness among UEF (1.412 N·m/deg), NEF (1.398 N·m/deg), LCP (1.128 N·m/deg), and E-LCP (0.838 N·m/deg). No structural failures occurred during fatigue testing spanning 108,000 cycles. In ultimate load tests, NEF withstood the highest load, followed sequentially by LCP, UEF, and E-LCP. Significant differences were found between the groups (p < 0.05), with frame bending and secondary bone fractures noted in post-test evaluations.

conclusionsThe NEF for tibial fractures is well-designed to meet the fracture healing requirements. It has certain advantages in comparison with other fixation methods and can be used as a new method for the treatment of tibial fractures.

Indexed as

External FixatorsFinite Element AnalysisFracture FixationTibial FracturesBiomechanical PhenomenaBone PlatesHumansBiomechanical testingExternal fixation deviceFinite element analysisTibial fracture

Identifiers

PMID40148896
PMCPMC11951732

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.