Evidence map›Paper›PMID 40148446›Full record

ArticleScientific reports2025

A comparative study on the efficacy of two different types of intracranial stent retrievers based on finite element simulation.

Yong Wu, Kejia Zhao, Yunhan Cai, Yibin Fang, Shengzhang Wang

Abstract readComparative Study
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yong WuYiwu Research Institute of Fudan University, Zhejiang, China.
Kejia ZhaoInstitute of Biomedical Engineering Technology, School of Engineering and Applied Technology, Fudan University, Shanghai, China.
Yunhan CaiInstitute of Biomechanics, Department of Aeronautics and Astronautics, Fudan University, Shanghai, China.
Yibin FangTongji University Affiliated Shanghai Fourth People's Hospital, Shanghai, China. fangyibin@163.com.
Shengzhang WangYiwu Research Institute of Fudan University, Zhejiang, China. szwang@fudan.edu.cn.

Funding

National Natural Science Foundation of China 11872152
6 · The paper itself

Abstract

This study investigates the thrombectomy performance of open (Solitaire FR 6 × 30) and closed (Trevo XP ProVue 6 × 25) stent retrievers in patient-specific vasculature using finite element analysis (FEA). The aim is to inform stent design optimization and improve surgical strategies. Patient-specific vascular models, thrombus models, and stent retriever models were constructed using CAD software. FEA simulated the thrombectomy procedure, and the simulation results were validated through in vitro experiments. The FEA predicted successful thrombus retrieval with the Solitaire FR 6 × 30, consistent with in vitro findings. Conversely, the Trevo XP ProVue 6 × 25 failed to retrieve the thrombus in the simulation. During Solitaire FR 6 × 30 thrombectomy, maximum thrombus stress (48.733 MPa), strain (2.257) and contact pressure on the vessel wall (7.177 MPa) were substantially higher than those observed during Trevo XP ProVue 6 × 25 thrombectomy (15.824 MPa, 1.554, and 1.872 MPa, respectively). Specifically, the Solitaire FR 6 × 30 induced 3.19 times greater maximum thrombus stress, 1.45 times greater maximum thrombus strain, and 2.83 times greater maximum vessel wall contact pressure. These findings suggest that the Solitaire FR stent retriever demonstrates superior thrombectomy efficacy compared to the Trevo XP stent retriever, likely attributable to its higher radial support force. However, the increased force exerted on the thrombus and vessel wall by the Solitaire FR raises the potential risk of thrombus fragmentation and vascular injury.

Indexed as

StentsThrombectomyComputer SimulationFinite Element AnalysisHumansModels, CardiovascularThrombosisFinite element simulationIn vitro experimentIschemic strokeStent retriever

Identifiers

PMID40148446
PMCPMC11950397

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.