ArticlePLoS computational biology2025
Investigation of hemodynamic bulk flow patterns caused by aortic stenosis using a combined 4D Flow MRI-CFD framework.
Article in PLoS computational biology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Hemodynamic Effects of Aortic Stenosis on Coronary Flow Dynamics.Annals of biomedical engineering · 2026Article
- Development of a Novel Holistic Assessment Strategy of TAVI-Induced Flow Restoration via Dimensionality Reduction Techniques.Cardiovascular engineering and technology · 2026Article
- Utility of Computational Modeling in Reassessing the Threshold for Intervention and Progression into Type A Aortic Dissection.Biomedicines · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Aortic stenosis (AS) leads to alterations of supra-valvular flow patterns which can cause increased damage of red blood cell (RBC) membranes. We investigated these patient specific patterns of a severe AS patient and their reversal in healthy flow through a 4D Flow MRI-based CFD methodology. Computational models of subject-specific aortic geometries were created using in-vivo medical imaging data. Temporally and spatially resolved boundary conditions derived from 4D Flow MRI were implemented for an AS patient and a healthy subject. After validation of the in-silico results with in-vivo data, a healthy inflow profile was set for the AS patient in the CFD model. Pathological versus healthy flow fields were compared regarding their blood flow characteristics, i.e., shear stresses on RBCs and helicity. The accuracy of the 4D Flow MRI-based CFD model was proven with excellent agreement between in-vivo and in-silico velocity fields and R² = 0.9. A pathological high shear stress region in the bulk flow was present during late systole with an increase of 125% compared to both healthy flow. The physiological bihelical structure with predominantly right-handed helices vanished for the pathological state. Instead, a left-handed helix appeared, accompanied by an overall increase in turbulent kinetic energy in areas of accumulated left-handed helicity. The validated 4D Flow MRI-based CFD model identified marked differences between AS and healthy flow. It suggests that altered turbulent and helical structures in the bulk flow are the cause for increased, potentially damaging forces acting upon RBCs in AS.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials