Evidence map›Paper›PMID 40144302›Full record

ArticleOrthopaedic journal of sports medicine2025

Mechanical Properties of Tibialis Tendon Grafts Are Unchanged by Soaking in Tobramycin.

Michael Burton, Tyler Barker, Zachary Burnett, Robert Magnussen, Christopher Kaeding, Eric Milliron, Parker Cavendish, Franco Piscitani, Jeremy Seidt, David Flanigan

Abstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Michael BurtonBoonshoft School of Medicine, Wright State University, Dayton, Ohio, USA.
Tyler BarkerSports Medicine Research Institute, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Zachary BurnettDepartment of Orthopedics, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Robert MagnussenDepartment of Orthopedics, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Christopher KaedingDepartment of Orthopedics, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Eric MillironDepartment of Orthopedics, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Parker CavendishDepartment of Orthopedics, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Franco PiscitaniSports Medicine Research Institute, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Jeremy SeidtDepartment of Mechanical and Aerospace Engineering, College of Engineering, The Ohio State University, Columbus, Ohio, USA.
David FlaniganSports Medicine Research Institute, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Tendon graft soaking in vancomycin solution minimizes surgical infection risk and has no effect on graft strength, but the intermittent vancomycin shortages, presence of vancomycin-resistant organisms, and treatment needs of patients with vancomycin hypersensitivity merit investigation of alternative antibiotics. Tobramycin prevents infection at low concentrations and is a cost-effective alternative, but it is unknown if tobramycin alters graft mechanical properties. Purpose/Hypothesis: The purpose of this study was to investigate the effects of tobramycin soaking on tendon graft mechanical properties. It was hypothesized that tobramycin soaking will not affect tendon graft mechanical properties. Study Design: Controlled laboratory study. Methods: A total of 30 tibialis tendon grafts were wrapped in saturated gauze swabs containing saline (control; n = 10), vancomycin (n = 10; 5 mg/mL), or tobramycin (n = 10; 1 mg/mL) for 10 minutes. Grafts were then removed from the treated gauze swab wraps and mechanically tested under uniaxial tension loading conditions. Grafts were pulled at a rate of 10 mm/min to failure. Force and displacement data from each test were used to calculate the Young modulus (MPa), ultimate tensile stress (MPa), and elasticity limit (MPa). Results: There were no significant differences in Young modulus (552 ± 108, 583 ± 98, and 660 ± 237 MPa; Conclusion: Soaking of tibialis tendon grafts with tobramycin does not appear to alter mechanical properties of the tendon graft under uniaxial load conditions. Clinical Relevance: If vancomycin use is not possible or contraindicated for certain patients, surgeons can soak grafts in tobramycin to achieve similarly effective infection mitigation without weakening the graft.

Indexed as

elasticity limitgraftmechanical propertiesseptic arthritissoakingtobramycinultimate tensile stressvancomycinYoung modulus

Identifiers

PMID40144302
PMCPMC11938474

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.