Evidence map›Paper›PMID 40143514›Full record

ArticleMedical physics2025

Commissioning of a precision preclinical 200 kV x-ray irradiator based on modular adaptations.

Lorenz Wolf, Peter Kuess, Sabine Leitner, Dietmar Georg, Barbara Knäusl

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Lorenz WolfDivision of Medical Physics, Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria.ORCID https://orcid.org/0000-0001-6596-3869
Peter KuessDivision of Medical Physics, Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria.ORCID https://orcid.org/0000-0003-2961-1692
Sabine LeitnerCompetence Centre for Preclinical Imaging and Biomedical Engineering, Faculty of Health, University of Applied Sciences, Wiener Neustadt, Austria.
Dietmar GeorgDivision of Medical Physics, Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria.ORCID https://orcid.org/0000-0002-8327-3877
Barbara KnäuslDivision of Medical Physics, Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria.ORCID https://orcid.org/0000-0003-4031-1711

Funding

Austrian Science Fund DFH 13-BFederal Ministry of Education, Science and Research of Austria
6 · The paper itself

Abstract

backgroundPreclinical research in radiation oncology encompasses a range of methodologies, including in vitro cell studies and in vivo small animal experiments, as well as in silico studies to evaluate radiation-induced side effects and tumor responses. PURPOSE: This study addresses the need for high-precision x-ray irradiation solutions as reference for preclinical research. Modifications of an industrial kilovoltage x-ray unit, along with the commissioning of a commercial treatment planning system (TPS), aimed to enable reliable irradiation of small animals in a horizontal beam geometry. All advancements enhancing the irradiation framework are made available, offering cost-effective upgrades for existing systems.

methodsAn industrial kilovoltage x-ray unit was equipped with a dual collimation system, featuring a fixed primary and variable secondary collimators with aperture diameters of 5 to 30 mm. Additional modular adaptations were designed and manufactured, including a multimodal mouse bedding unit, a dedicated dosimetry phantom and a quality assurance (QA) phantom. Output factors, percentage depth dose curves and lateral dose profiles were acquired to generate a beam model in the

resultsThe resulting beam model was validated within a maximum dose deviation of 1.7%. Aperture diameters close to potential target diameters were found to be effective for achieving sufficient target coverage in silico, as demonstrated for a 5 mm target with a homogeneity index of (9.9

conclusionsCost-effective adaptations for an kilovoltage x-ray irradiation framework were designed, manufactured and commissioned, and contribute to the accessibility of preclinical irradiation research. These components are integrated into a comprehensive preclinical particle beam platform.

Indexed as

Equipment and SuppliesX-RaysAnimalsMicePhantoms, ImagingRadiometryRadiotherapy DosageRadiotherapy Planning, Computer-Assistedpreclinical researchsmall animal irradiationx‐ray

Identifiers

PMID40143514
PMCPMC12149721

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.