Evidence map›Paper›PMID 40142084›Full record

ArticleMolecules (Basel, Switzerland)2025

Simultaneous Measurements of Nanotrace Amounts of Lead and Cadmium Using an Environmentally Friendly Sensor (An Activated Glassy Carbon Electrode Modified with a Bismuth Film).

Katarzyna Tyszczuk-Rotko, Aleksy Keller

Abstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Katarzyna Tyszczuk-RotkoFaculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland.ORCID 0000-0001-5893-5309
Aleksy KellerFaculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland.ORCID 0009-0008-8802-9719

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper shows the fabrication of a new environmentally friendly sensor, an activated glassy carbon electrode with an in situ deposited bismuth film (aGCE/BiF), to determine Cd(II) and Pb(II) at the nanotrace level. The electrochemical activation of the GCE surface was achieved in a solution of 0.1 M phosphate-buffered saline (PBS) of pH = 7 by performing five cyclic voltammetric scans in the range of -1.5-2.5 V at ν of 100 mV/s. The newly developed electrode provides several advantages, such as an increased electron active surface (compared to the glassy carbon electrode) and improved electron transfer kinetics. As a result, the new voltammetric procedure (square-wave anodic stripping voltammetry, SWASV) was established and optimized. With the SWASV method, the following calibration curves and low detection limits (LODs) were obtained for Cd(II) and Pb(II), respectively: 5-100 nM, 0.62 nM, 2-200 nM, and 0.18 nM. The newly prepared method was used to determine the amounts of Pb(II) and Cd(II) in the certified reference material, and the results agreed with the certified values. Moreover, the procedure was successfully applied to determine the Cd(II) and Pb(II) in river samples. The official and standard addition methods validated the measurement results.

Indexed as

activated glassy carbon electrode with in situ deposited bismuth filmenvironmentally friendly sensorlead and cadmium measurementsstripping voltammetrywater samples

Identifiers

PMID40142084
PMCPMC11944615

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.