Evidence map›Paper›PMID 40141960›Full record

ArticleMicromachines2025

Scanning Mirror Benchmarking Platform Based on Two-Dimensional Position Sensitive Detector and Its Accuracy Analysis.

Hexiang Guo, Junya Wang, Zheng You

Abstract read
In one paragraph

Article in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Hexiang GuoSchool of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
Junya WangSchool of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
Zheng YouSchool of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.

Funding

the funding of the 2023 Smart Sensor Key Special Young Scientist Project 2023YFB3208700
6 · The paper itself

Abstract

A MEMS scanning mirror is a beam scanning device based on MEMS technology, which plays an important role in the fields of Lidar, medical imaging, laser projection display, and so on. The accurate measurement of the scanning mirror index can verify its performance and application scenarios. This paper designed and built a scanning mirror benchmark platform based on a two-dimensional position-sensitive detector (PSD), which can accurately measure the deflection angle, resonance frequency, and angular resolution of the scanning mirror, and described the specific test steps of the scanning mirror parameters, which can meet the two-dimensional measurement. Secondly, this paper analyzed and calculated the angular test uncertainty of the designed test system. After considering the actual optical alignment error and PSD measurement error, when the distance between the PSD and MEMS scanning mirror is 100 mm, the range of mechanical deflection angle that can be measured is (-6.34°, +6.34°). When the mechanical deflection angle of the scanning mirror is 0.01°, the accuracy measured by the test system is 0.00097°, and when the mechanical deflection of the scanning mirror is 6.34°, the accuracy measured by the test system is 0.011°. The test platform has high accuracy and can measure the parameters of the scanning mirror accurately.

Indexed as

2D-PSDaccuracy analysisbenchmark test platformMEMS scanning mirror

Identifiers

PMID40141960
PMCPMC11945176

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.