Evidence map›Paper›PMID 40141883›Full record

ArticleMicromachines2025

Design and Simulation of Magnetic Shielding Structure Based on Closed-Loop TMR Current Sensor.

Qiuyang Li, Suqin Xiong, Shuo Wang, Xianguang Dong, Haifeng Zhang

Abstract read
In one paragraph

Article in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Qiuyang LiChina Electric Power Research Institute Co., Ltd., Beijing 100192, China.
Suqin XiongChina Electric Power Research Institute Co., Ltd., Beijing 100192, China.
Shuo WangMEMS Center, Harbin Institute of Technology, Harbin 150001, China.
Xianguang DongState Grid Shandong Electric Power Company Marketing Service Center (Metrology Center), Jinan 250001, China.
Haifeng ZhangMEMS Center, Harbin Institute of Technology, Harbin 150001, China.ORCID 0000-0002-4917-746X

Funding

State Grid Corporation of China 5700-202141452A-0-0-00
6 · The paper itself

Abstract

With the rapid development of current sensor technology, tunnel magnetoresistance (TMR) current sensors have been widely adopted in industrial detection due to their high sensitivity, excellent linearity, and broad measurement range. This study focuses on closed-loop TMR current sensors, utilizing COMSOL Multiphysics 6.2 software and the finite element method to conduct an in-depth analysis of structural parameters affecting sensor sensitivity. A novel magnetic shielding package architecture is proposed and designed. Simulation results demonstrate that the shielding efficiency of this structure improves by 44.3% compared to a single magnetic ring under a stray magnetic field of 0.1 mT along the sensing axis. At the same time, the measurement accuracy is 2.1 times higher than that of traditional structures. Current detection experiments conducted in a strong magnetic field environment further validate that the shielding package effectively suppresses external electromagnetic interference, significantly enhancing sensor stability and measurement accuracy. This research provides important theoretical and practical insights for applying high-precision TMR current sensors in complex electromagnetic environments.

Indexed as

closed-loop TMR current sensorCOMSOL Multiphysicscurrent sensorshielded structure

Identifiers

PMID40141883
PMCPMC11944719

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.