Evidence map›Paper›PMID 40141543›Full record

ArticleMaterials (Basel, Switzerland)2025

A Comparative Analysis of ProTaper Ultimate and Five Multifile Systems: Design, Metallurgy, and Mechanical Performance.

Jorge N R Martins, Emmanuel João Nogueira Leal Silva, Victor Talarico Leal Vieira, Rui Pereira da Costa, Abayomi O Baruwa, Francisco Manuel Braz Fernandes, Marco Aurélio Versiani

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jorge N R MartinsFaculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal.ORCID 0000-0002-6932-2038
Emmanuel João Nogueira Leal SilvaDepartment of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro 21210-623, Brazil.ORCID 0000-0002-6445-8243
Victor Talarico Leal VieiraDepartment of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro 21210-623, Brazil.ORCID 0000-0001-6434-2622
Rui Pereira da CostaFaculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal.ORCID 0000-0001-8043-7189
Abayomi O BaruwaDepartment of Clinical Sciences, College of Dentistry, Ajman University, Ajman P.O. Box 346, United Arab Emirates.ORCID 0000-0002-1670-8674
Francisco Manuel Braz FernandesCENIMAT/I3N, Department of Materials Science, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal.
Marco Aurélio VersianiDental Specialty Center, Brazilian Military Police, Belo Horizonte 30350-190, Brazil.

Funding

Fundação para a Ciência e a Tecnologia, I.P. (FCT) UIDB/50025/2020-2023
6 · The paper itself

Abstract

The present research compared the design, metallurgical properties, and mechanical characteristics of the ProTaper Ultimate instruments with five multifile systems. A total of 469 new nickel-titanium rotary finishing instruments, all 25 mm in length but varying in size, taper, and metal alloy composition, from six different multifile systems (ProTaper Ultimate, ProTaper Next, ProFile, Mtwo, EndoSequence, and GT Series X), were inspected for irregularities and analyzed for their spiral density (spirals per millimetre), blade design, surface finishing, alloy composition, phase transformation temperatures, and mechanical performance (microhardness, torsional, and bending resistance tests). Group comparisons were performed using Kruskal-Wallis and one-way ANOVA with post hoc Tukey's tests (α = 5%). ProFile instruments exhibited a greater number of spirals and a higher density of spirals per millimetre compared to the other systems. Microscopic analysis revealed distinct tip geometries and blade designs among tested instruments. All of them displayed parallel marks from the machining process, but the EndoSequence system had the smoothest surface finish. The alloys of all instruments consisted of an almost equiatomic ratio of nickel to titanium. At the testing temperature, the ProTaper Ultimate system exhibited a complete R-phase crystallographic arrangement, while the ProFile and Mtwo systems were fully austenitic. The ProTaper Ultimate F2, F3, and FX instruments demonstrated the highest maximum torque values (1.40, 1.45, and 3.55 N.cm, respectively) and the lowest maximum bending loads (202.7, 254.9, and 408.4 gf, respectively). EndoSequence instruments showed the highest angles of rotation, while the highest microhardness values were recorded for GT Series X (407.1 HVN) and ProTaper Next (425.0 HVN) instruments. The ProTaper Ultimate system showed a high spiral density per millimetre and a complete R-phase crystallographic arrangement at room temperature, which significantly contributed to its superior flexibility and torsional strength when compared to the other tested systems.

Indexed as

bending loaddifferential scanning calorimetryendodonticsnickel-titanium alloyroot canal treatmenttorsional strength

Identifiers

PMID40141543
PMCPMC11943969

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.