Evidence map›Paper›PMID 40140542›Full record

ArticleScientific reports2025

Transfer of patients' tibiofemoral kinematics and loads to a six-degree-of-freedom (6-DOF) joint simulator under consideration of virtual ligaments.

Paul Henke, Leo Ruehrmund, Jessica Hembus, Sven Krueger, Rainer Bader, Maeruan Kebbach

Abstract readEvaluation Study
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Paul Henke *Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany. paul.henke@med.uni-rostock.de.
Leo Ruehrmund *Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany.
Jessica HembusDepartment of Orthopaedics, Rostock University Medical Center, Rostock, Germany.
Sven KruegerResearch and Development, Aesculap AG, Tuttlingen, Germany.
Rainer BaderDepartment of Orthopaedics, Rostock University Medical Center, Rostock, Germany.
Maeruan KebbachDepartment of Orthopaedics, Rostock University Medical Center, Rostock, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Preclinical testing of total knee replacements (TKR) is crucial for evaluating new implant designs. Dynamic experimental testing focus mostly on level walking and squats, failing to represent a full range of daily activities. Moreover, the contribution of the ligament apparatus is often simplified. Therefore, this study transferred five daily activity load cases-level walking, downhill walking, stair descent, squat, and sit-to-stand-onto a six-degree-of-freedom (6-DOF) joint simulator with a cruciate-retaining bicondylar TKR and a virtual ligament apparatus. Forces and kinematics were based on telemetric data from an ultra-congruent TKR. The resulting kinematics, kinetics, and tibiofemoral contact surfaces were evaluated. Additionally, variations of the virtual ligament apparatus on the joint simulator, e.g. resection of the posterior cruciate ligament (PCL), have been used to assess its influence on the resulting joint dynamics. Results showed that tibiofemoral contact area was more influenced by dynamics than kinematics. Virtual PCL resection shifted the tibia posteriorly (up to 3 mm) and increased abduction (up to 0.5°). Different results were seen across all load cases. The exceptions are the squat and sit-to-stand load cases with similar patterns. Thus, cruciate-retaining TKR can be tested using telemetric data from ultra-congruent TKR, aiding in comprehensive evaluations.

Indexed as

Biomechanical PhenomenaComputer SimulationKnee JointPosterior Cruciate LigamentRange of Motion, ArticularArthroplasty, Replacement, KneeFemurHumansKnee ProsthesisProsthesis DesignReference ValuesTibiaWalkingWeight-BearingActivities of daily livingBiomechanical testingLigament apparatusSix-degree-of-freedom joint simulatorTotal knee replacement

Identifiers

PMID40140542
PMCPMC11947412

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.