Evidence map›Paper›PMID 40140173›Full record

ArticleOdontology2025

Monomer release, cytotoxicity, and surface roughness of temporary fixed prosthetic materials produced by digital and conventional methods.

Zeynep Sahin, Deniz Ozkan Vardar, Ekin Erdogmus, Semih Calamak, Belma Koçer Gumusel

Abstract read
In one paragraph

Article in Odontology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Polishing of provisional crown materials: the effects onThe journal of advanced prosthodontics · 2026
    Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Zeynep SahinDepartment of Prosthodontics, Faculty of Dentistry, Lokman Hekim University, Ankara, Turkey. dtsahinzeynep81@gmail.com.ORCID http://orcid.org/0000-0003-2459-2912
Deniz Ozkan VardarLokman Hekim University, Vocational School of Health Services, Pharmacy Services Program, Ankara, Turkey.ORCID http://orcid.org/0000-0003-0976-9556
Ekin ErdogmusDepartment of Pharmaceutical Toxicology, Faculty of Pharmacy, Lokman Hekim University, Ankara, Turkey.ORCID http://orcid.org/0000-0002-5097-8889
Semih CalamakDepartment of Basic Pharmaceutical Sciences, Faculty of Pharmacy, Lokman Hekim University, Ankara, Turkey.ORCID http://orcid.org/0000-0002-0989-6400
Belma Koçer GumuselDepartment of Pharmaceutical Toxicology, Faculty of Pharmacy, Okan University, İstanbul, Turkey.ORCID http://orcid.org/0000-0003-4311-2291

Funding

Bilimsel Araştırma Projeleri Birimi, Lokman Hekim Üniversitesi TSA-2023-41
6 · The paper itself

Abstract

This study compared surface roughness, monomer release, and, cytotoxicity of temporary fixed prosthetic materials manufactured using the conventional, CAD/CAM milling and 3D printing methods. Disc-shaped samples (2 mm height, 5 mm diameter) were prepared from four materials [polyethyl methacrylate/polymethyl methacrylate (Dentalon Plus-DP), bis-acrylic composite resin (Protemp 4-PT), polymethyl methacrylate CAD/CAM disc (On Dent), and methacrylate-based resin (QuraCROWN Temp)]. Surface roughness was measured with a profilometer; scanning electron microscopy (SEM) was used for surface characterization. Following 24, 72, and 120 h of artificial saliva incubation for the samples, the obtained extracts were evaluated for cytotoxicity by performing 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) test in the mouse fibroblast cell. Monomer release from the test samples was analyzed by High‑Performance Liquid Chromatography. Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy (ATR-FTIR) was performed to evaluate the chemical composition of artificial saliva extracts. Cell viability was assessed by one-way ANOVA, and surface roughness by Kruskal-Wallis and Mann-Whitney U tests. No monomer was detected in artificial saliva for any materials. The FTIR spectroscopy of the extracts did not show any peaks corresponding to these monomer or polymer structures, indicating that no residual monomer or polymer was released into the artificial saliva after exposure to artificial saliva. 3D-printed materials were significantly more cytotoxic than the other three test materials at all time points and dilutions (p < 0.05). The highest cell viability rates were detected in CAD/CAM milling (99.43 ± 3.79) at 24 h and PT materials (100.47 ± 5.31) at 72 h for 1:8 dilution. At 1:4 dilution, except for the DP-3D printing test groups, the other groups show similar cell viability rates with the control group (p > 0.05). Digitally manufactured materials had lower roughness than conventionally produced ones (p < 0.05). CAD/CAM milling and PT materials were the most biocompatible, while 3D-printed material was found to be cytotoxic. CAD/CAM milling and PT materials may offer safe and effective options for temporary prosthetic restorations. Although DP showed acceptable results, it was less effective than CAD/CAM milling and PT materials. Due to their cytotoxicity, 3D-printed materials require further investigation before clinical use.

Indexed as

Computer-Aided DesignDental MaterialsDental Restoration, TemporaryAnimalsCell SurvivalComposite ResinsFibroblastsMaterials TestingMiceMicroscopy, Electron, ScanningPolymethyl MethacrylatePrinting, Three-DimensionalSaliva, ArtificialSpectroscopy, Fourier Transform InfraredSurface PropertiesComposite ResinsDental MaterialsPolymethyl MethacrylateSaliva, Artificial3D printingCAD/CAMCytotoxicityHPLCTemporary restorative materials

Identifiers

PMID40140173
PMCPMC12450830

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.