ReviewPediatric cardiology2026
Largest Single-Center Experience Using the Micro Vascular Plug (MVP) for Transcatheter Closure of Premature Patent Ductus Arteriosus.
Review in Pediatric cardiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Within the last 5 years, the FDA approved use of the Amplatzer Piccolo Occluder (Abbot Structural Heart, CA) for transcatheter patent ductus arteriosus (PDA) closure in premature infants. Other devices have been used off-label to successfully perform this procedure, including the Microvascular Plug, "MVP" (Medtronic, Minneapolis, MN). We report the largest single-center experience with PDA closure in premature infants using the MVP device. A retrospective review of transcatheter premature infant PDA closures at a single center was performed. Procedures performed using the MVP device were included; procedures using other devices were excluded. Descriptive statistics were performed using R version 4.4.0. From 4/2018 to 8/2022, a total of 74 cases were performed. The median gestational age was 24 (IQR 23-25) weeks and procedural weight was 1.17 kg (0.97-1.40); (82% ≤ 1.5 kg). The age at procedure was 44 days (34-54). PDA minimum diameter (by angiogram) was 2.85 (2.4-3.4) mm. There were no procedural or 30-day mortalities. There was one major Adverse Event (AE) (aortic arch obstruction; 1.3%). There were two minor AEs (2.6%; small pericardial effusion requiring no intervention, n = 1; and device malposition with uneventful retrieval and replacement of additional device within the same catheterization, n = 1). The left pulmonary artery peak gradient at most recent follow-up was 5.8 (3.4-8.9) mmHg; the aortic peak gradient was 0.77 (0.4-1.7). There is a median follow-up time of 63 days (32-310) post-procedure. The safety profile using the MVP is in line with or favorable compared to the contemporary literature of PDA closure in premature infants.
Indexed as
Identifiers
40140105What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.