Evidence map›Paper›PMID 40138073›Full record

ArticleThe ultrasound journal2025

Examiner experience moderates reliability of human lower extremity muscle ultrasound measurement - a double blinded measurement error study.

Konstantin Warneke, Stanislav D Siegel, Jonas Drabow, Lars H Lohmann, Daniel Jochum, Sandro R Freitas, José Afonso, Andreas Konrad

Abstract read
In one paragraph

Article in The ultrasound journal, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Trial
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Konstantin WarnekeDepartment for Movement Science and Exercise Physiology, Friedrich Schiller University Jena, Jena, Germany. Konstantin.Warneke@uni-jena.de.ORCID http://orcid.org/0000-0003-4964-2867
Stanislav D SiegelDepartment for Movement Science and Exercise Physiology, Friedrich Schiller University Jena, Jena, Germany.
Jonas DrabowDepartment for Movement Science and Exercise Physiology, Friedrich Schiller University Jena, Jena, Germany.
Lars H LohmannDepartment for Movement Science and Exercise Physiology, Friedrich Schiller University Jena, Jena, Germany.
Daniel JochumDepartment of Health Science and Technology, ETH Zürich, Zürich, Switzerland.
Sandro R FreitasNeuromuscular Research Lab, Faculty of Human Kinetics, University of Lisbon, Lisbon, Portugal.
José AfonsoCentre of Research, Education, Innovation, and Intervention in Sport (CIFI 2 D), Faculty of Sport, University of Porto, Porto, Portugal.
Andreas KonradInstitute of Human Movement Science, Sport and Health, University of Graz, Graz, Austria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Structural muscle properties are critical in health and athletic settings, with magnetic resonance imaging considered the gold standard assessment procedure under static conditions due to its reliability and objectivity. Practical limitations, including cost and accessibility, have led to the increasing use of ultrasound as an alternative for skeletal muscle morphological parameters. However, ultrasound measurements are sensitive to evaluation conditions and assessor experience, which has not been sufficiently explored, yet. Therefore, this study investigated the influence of assessor experience on the reliability of ultrasound measurements. A double-blind design was used, involving an experienced assessor (> 12,000 images for several years) and multiple inexperienced assessors (< 100 images) to collect data from 39 recreationally active participants. Measurements of muscle architecture were conducted in the leg muscles over two consecutive days, generating 1,248 ultrasound images. Relative and absolute reliability were analyzed using intraclass correlation coefficients (ICCs), standard error of measurement, minimal detectable change, mean absolute error (MAE), mean absolute percentage error (MAPE) and Bland-Altman analyses. Relative reliability was good to excellent in all measurement spots and time-points for muscle thickness (ICC = 0.76-0.98) irrespective of assessor experience, except for the inter-day comparison for the gastrocnemius lateralis by the inexperienced assessors, (ICC = 0.58). The pennation angle assessment ranged from insufficient to excellent reliability (ICC = 0.18-0.94) and experience contributed greatly to better results. The random error for the inexperienced assessors was reflected in two- to three-times higher MAEs/MAPEs and limits of agreement in the Bland-Altman analyses, respectively. The findings emphasize the importance of experience and standardization in achieving reliable ultrasound data, particularly for (a) sensitive parameters like the pennation angle and/or (b) inter-day, intra-subject comparisons.

Indexed as

AgreementIntraclass correlation coefficientMuscle thicknessPennation angleSonography

Identifiers

PMID40138073
PMCPMC11947354

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.