Evidence map›Paper›PMID 40135247›Full record

ArticleSmall (Weinheim an der Bergstrasse, Germany)2025

Dissolvable Probiotic-Powered Biobatteries: A Safe and Biocompatible Energy Solution for Transient Applications.

Maryam Rezaie, Maedeh Mohammadifar, Seokheun Choi

Abstract read
In one paragraph

Article in Small (Weinheim an der Bergstrasse, Germany), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Maryam RezaieBioelectronics & Microsystems Laboratory, Department of Electrical & Computer Engineering, State University of New York at Binghamton, Binghamton, NY, 13902, USA.
Maedeh MohammadifarBioelectronics & Microsystems Laboratory, Department of Electrical & Computer Engineering, State University of New York at Binghamton, Binghamton, NY, 13902, USA.
Seokheun ChoiBioelectronics & Microsystems Laboratory, Department of Electrical & Computer Engineering, State University of New York at Binghamton, Binghamton, NY, 13902, USA.ORCID 0000-0003-1097-2391

Funding

National Science Foundation 2246975National Science Foundation 2410431SUNY System Administration 241000
6 · The paper itself

Abstract

For decades, science fiction has imagined electronic devices that spring to life on demand, function as programmed, and then vanish without a trace. Today, transient and bioresorbable electronics are making that vision a reality, sparking revolutionary progress in biomedicine, environmental stewardship, and hardware security. Yet one critical barrier remains: a fully transient power source with the same disappearing act. Microbial-based biobatteries have emerged as strong contenders, harnessing the power of microorganisms-found virtually everywhere-as natural biocatalysts. However, toxicity and health risks have limited these systems to single-use, often incinerable applications. Here, a transformative approach: a transient biobattery powered by commercially available probiotics that dissolves harmlessly is introduced, releasing only beneficial microbes. Fabricated on water-soluble or pH-responsive substrates, this biobattery capitalizes on a 15-strain probiotic blend to generate electricity across diverse electrode materials. By manipulating device length or encapsulating it with pH-sensitive polymers, power delivery can be fine-tuned from 4 min up to over 100 min. A single module outputs 4 µW of power, 47 µA of current, and an open-circuit voltage of 0.65 V. This groundbreaking design ushers in a new era of safe, effective transient bioenergy systems, opening unprecedented opportunities in biomedical implants, environmental sensors, and disposable electronics.

Indexed as

Biocompatible MaterialsBioelectric Energy SourcesProbioticsElectrodesHydrogen-Ion ConcentrationBiocompatible Materialsbiocompatiblebioresorbable electronics transient biobatterybiosafeprobiotic biocatalyststransient electronics

Identifiers

PMID40135247
PMCPMC12067177

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.