Evidence map›Paper›PMID 40132957›Full record

ArticleAnalytical chemistry2025

Improving Meropenem Quantification in a Compact SERS-Based Centrifugal Microfluidic Platform: Toward TDM of Antibiotics in ICU.

Martyna A Pytlarz, Gohar Soufi, Isidro Badillo-Ramírez, Laura Serioli, Roman Slipets, Anders Perner, Anja Boisen

Abstract read
In one paragraph

Article in Analytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. SERS-Based Nano- and Microsystems Toward Biomedical Applications.Small (Weinheim an der Bergstrasse, Germany) · 2026
    Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Martyna A PytlarzCenter for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Lyngby, Kongens 2800, Denmark.
Gohar SoufiCenter for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Lyngby, Kongens 2800, Denmark.ORCID 0009-0006-3994-5580
Isidro Badillo-RamírezCenter for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Lyngby, Kongens 2800, Denmark.
Laura SerioliCenter for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Lyngby, Kongens 2800, Denmark.ORCID 0000-0003-3502-0178
Roman SlipetsCenter for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Lyngby, Kongens 2800, Denmark.ORCID 0000-0001-7196-5561
Anders PernerDepartment of Intensive Care, Copenhagen University Hospital-Rigshospitalet, Copenhagen 2100, Denmark.
Anja BoisenCenter for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Lyngby, Kongens 2800, Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Infections are the leading causes of death, especially in intensive care units (ICUs), necessitating immediate and optimal antibiotic treatment with proper monitoring of the drug dosage. Present analytical techniques measuring antibiotic levels result in a long lag time for dose adjustments. Therefore, introducing versatile techniques that quickly quantify antibiotic levels in a patient's blood is essential. We developed a novel approach to advance the automation of label-free surface-enhanced Raman spectroscopy (SERS) in a centrifugal microfluidic setting (D-SERS device) to improve the quantification of meropenem (MER) in serum samples. The D-SERS device consists of a microfluidic disc cartridge, a spin motor, and an integrated Raman spectrometer module. In our assay method, we implemented a serum cleanup step, employing a monospin solid-phase extraction (ms-SPE) column, which was coupled with the D-SERS device. The MER label-free detection was performed on-disc by SERS scanning of a Ag nanopillar substrate integrated into the disc cartridge. We identified that coupling ms-SPE to the D-SERS device led to significant improvement in a signal-to-noise ratio and sensitivity. Chemometrics algorithms, such as partial least squares regression (PLSR), were implemented on a large data set for SERS analysis, allowing LoD and LoQ values of 12.12 and 36.37 μM, respectively. We compared the performance of our D-SERS device to that of a commercial Raman system, demonstrating its efficiency and reliability. Moreover, the D-SERS device was validated against HPLC employing samples from ICU patients, showing a good correlation (

Indexed as

Anti-Bacterial AgentsDrug MonitoringLab-On-A-Chip DevicesMeropenemMicrofluidic Analytical TechniquesSpectrum Analysis, RamanCentrifugationHumansIntensive Care UnitsSolid Phase ExtractionAnti-Bacterial AgentsMeropenem

Identifiers

PMID40132957
PMCPMC12004356

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.