ArticleBMC medical imaging2025
Enhanced tuberculosis detection using Vision Transformers and explainable AI with a Grad-CAM approach on chest X-rays.
Article in BMC medical imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Deep learning for radiographic differentiation between lateral malleolar avulsion fractures and subfibular ossicles.iScience · 2026Article
- Metaheuristic-Optimized Convolutional Neural Network for Automated Diagnosis of Viral Pneumonia and Tuberculosis from Chest X-Rays.Diagnostics (Basel, Switzerland) · 2026Article
- Artificial Intelligence for Tuberculosis Screening and Detection: From Evidence to Policy and Implementation.Diagnostics (Basel, Switzerland) · 2026Review
- Class-attention pooling and token sparsity based vision transformers for chest X-ray interpretation.Scientific reports · 2026Article
- Ensemble deep learning architectures for detecting pulmonary tuberculosis in chest X-rays.Scientific reports · 2026Article
- Anatomy-Guided Hybrid CNN-ViT Model with Neuro-Symbolic Reasoning for Early Diagnosis of Thoracic Diseases Multilabel.Diagnostics (Basel, Switzerland) · 2026Article
- LPC-transformer: a training strategy optimized framework for multiclass pneumonia medical image classification.Frontiers in medicine · 2026Article
- Interpretable multimodal machine learning for diagnosis of drug-resistant tuberculosis.Frontiers in digital health · 2026Article
- SPX-GNN: An Explainable Graph Neural Network for Harnessing Long-Range Dependencies in Tuberculosis Classifications in Chest X-Ray Images.Diagnostics (Basel, Switzerland) · 2025Article
- Enhanced CoAtNet based hybrid deep learning architecture for automated tuberculosis detection in human chest X-rays.BMC medical imaging · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Tuberculosis (TB), caused by Mycobacterium tuberculosis, remains a leading global health challenge, especially in low-resource settings. Accurate diagnosis from chest X-rays is critical yet challenging due to subtle manifestations of TB, particularly in its early stages. Traditional computational methods, primarily using basic convolutional neural networks (CNNs), often require extensive pre-processing and struggle with generalizability across diverse clinical environments. This study introduces a novel Vision Transformer (ViT) model augmented with Gradient-weighted Class Activation Mapping (Grad-CAM) to enhance both diagnostic accuracy and interpretability. The ViT model utilizes self-attention mechanisms to extract long-range dependencies and complex patterns directly from the raw pixel information, whereas Grad-CAM offers visual explanations of model decisions about highlighting significant regions in the X-rays. The model contains a Conv2D stem for initial feature extraction, followed by many transformer encoder blocks, thereby significantly boosting its ability to learn discriminative features without any pre-processing. Performance testing on a validation set had an accuracy of 0.97, recall of 0.99, and F1-score of 0.98 for TB patients. On the test set, the model has accuracy of 0.98, recall of 0.97, and F1-score of 0.98, which is better than existing methods. The addition of Grad-CAM visuals not only improves the transparency of the model but also assists radiologists in assessing and verifying AI-driven diagnoses. These results demonstrate the model's higher diagnostic precision and potential for clinical application in real-world settings, providing a massive improvement in the automated detection of TB.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.