Evidence map›Paper›PMID 40128548›Full record

ArticleScientific reports2025

Full-length weight-bearing radiographs and computed tomography show discrepancies in coronal alignment for robotic arm-assisted total knee arthroplasty.

Hong Yeol Yang, Khairul Anwar Ayob, Hwi Woo Jeong, Jong Keun Seon

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hong Yeol YangDepartment of Orthopaedic Surgery, Chonnam National University Hwasun Hospital, College of Medicine, Chonnam National University, 322, Seoyang-ro, Hwasun, Chonnam, 58128, Republic of Korea.
Khairul Anwar AyobDepartment of Orthopaedic Surgery, National Orthopaedic Centre of Excellence for Research and Learning (NOCERAL), Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
Hwi Woo JeongDepartment of Orthopaedic Surgery, Chonnam National University Hwasun Hospital, College of Medicine, Chonnam National University, 322, Seoyang-ro, Hwasun, Chonnam, 58128, Republic of Korea.
Jong Keun SeonDepartment of Orthopaedic Surgery, Chonnam National University Hwasun Hospital, College of Medicine, Chonnam National University, 322, Seoyang-ro, Hwasun, Chonnam, 58128, Republic of Korea. seonbell@chonnam.ac.kr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Assessment of lower limb coronal plane alignment is crucial in surgical planning of total knee arthroplasty (TKA) and is commonly performed with full-length weight-bearing radiographs (FLWBR). The aim of this study was to determine discrepancies in coronal limb alignment as assessed by conventional FLWBR versus non-weight-bearing computed tomography (CT) modalities in robotic arm-assisted TKA. We retrospectively analyzed 100 consecutive patients with osteoarthritic knees who underwent robotic arm-assisted TKA with preoperative FLWBR and CT assessments of knee alignment. The mechanical axes of the Mako system were established in accordance with the Mako TKA Surgical Guide. The following parameters were compared between the two imaging modalities: (1) mechanical hip-knee-ankle angle (mHKA), (2) medial proximal tibial angle (MPTA), (3) lateral distal femoral angle (LDFA), (4) arithmetic hip-knee-ankle angle (aHKA), (5) joint line obliquity (JLO), and (6) proportion of the Coronal Plane Alignment of the Knee (CPAK) types. Regression analyses were performed to identify potential factors associated with discrepancies in measurements of coronal alignment between these two imaging modalities. There were significant differences in terms of the mHKA between preoperative CT and FLWBR (CT vs. FLWBR, 7.0° vs. 8.5°; p < 0.001), which may be attributed to the extent of the weight-bearing condition. The CT measurements with the Mako system demonstrated a lower (more varus) MPTA than the FLWBR measurements (CT vs. FLWBR, 83.7° vs. 85.2°; p < 0.001). Furthermore, there were also significant differences between the CT and FLWBR measurements in terms of the aHKA (-  4.7° vs. - 3.7°; p = 0.028) and JLO (172.2° vs. 174.2°; p < 0.001). There were significant differences of proportion of CPAK types between the two imaging modalities; however, the most common category was type I in both imaging modalities. Multivariate analyses showed that greater preoperative mHKA and posterior tibial slope were associated with the discrepancy in the MPTA measurements between the two imaging modalities. There were discrepancies in coronal alignment between preoperative FLWBR and non-weight-bearing CT using the Mako system. When compared with conventional FLWBR, the Mako system tended to overestimate the magnitude of tibial varus deformity in the knee joint.

Indexed as

Arthroplasty, Replacement, KneeOsteoarthritis, KneeRobotic Surgical ProceduresTomography, X-Ray ComputedAgedAged, 80 and overFemaleHumansKnee JointMaleMiddle AgedRadiographyRetrospective StudiesWeight-BearingCoronal alignmentCTFull-length weight-bearing radiographMakorobotic arm-assisted TKA

Identifiers

PMID40128548
PMCPMC11933405

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.