Evidence map›Paper›PMID 40124282›Full record

ArticleJB & JS open access

Accuracy of Acetabular Component Positioning Using a Mixed Reality-Guided Navigation System During Total Hip Arthroplasty.

Alexander F Heimann, William S Murphy, Daniel C Sun, Stephen B Murphy

Abstract read
In one paragraph

Article in JB & JS open access. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Alexander F HeimannCenter for Computer Assisted and Reconstructive Surgery, New England Baptist Hospital, Boston, Massachusetts.ORCID https://orcid.org/0000-0001-6578-5759
William S MurphyWashington University in St. Louis, St. Louis, Missouri.ORCID https://orcid.org/0000-0002-8884-3760
Daniel C SunTufts Medical Center, Boston, Massachusetts.ORCID https://orcid.org/0000-0001-9231-969X
Stephen B MurphyCenter for Computer Assisted and Reconstructive Surgery, New England Baptist Hospital, Boston, Massachusetts.ORCID https://orcid.org/0009-0009-2853-2037

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Surgeons increasingly recognize the importance of patient-specific considerations in determining ideal cup alignments. In addition, various surgical navigation systems have been reported to improve cup placement accuracy during total hip arthroplasty (THA). Recently, a novel computed tomography (CT)-based planning and mixed-reality (MR) guidance system was developed to enable patient-specific 3-dimensional planning of the ideal cup position and further improve intraoperative achievement of the planned orientation. Methods: This is retrospective, observational study of 40 patients (40 hips) who underwent MR-guided THA. Patient-specific CT-based surgical planning with definition of target operative anteversion and inclination of the acetabular cup in relation to the anterior pelvic plane was performed. 3D holograms of the cup and cup impactor in the selected target position were created and exported. Intraoperatively, automatic holographic registration was performed using a smart tool-based linked-paired-point matching method. Patient-specific content was displayed on a head-mounted display, and the acetabular component was inserted by matching the spatial position of the cup impactor with the hologram of the cup impactor in the target position. Postoperatively, patients underwent biplane simultaneous imaging for measurement of achieved cup alignment using a validated measurement method. Results: Mean planned operative anteversion and inclination angles were 28.4° ± 1.6° (95% confidence interval [CI], 27.9°-28.8°) and 39.9° ± 0.3° (95% CI, 39.8°-40.0°), respectively. The mean absolute target error between preoperative target operative anteversion and the achieved operative anteversion was 0.7° ± 1.1° (95% CI, 0.3°-1.0°; range, 0°-4°). The mean absolute target error between preoperative target operative inclination and the achieved operative inclination was 1.1° ± 1.2° (95% CI, 0.7°-1.4°; range, 0°-4°). Conclusion: Acetabular component positioning using a mixed reality guidance system during THA was highly accurate and well within the accuracy reported for other navigation systems. Level of Evidence: Level III. See Instructions for Authors for a complete description of levels of evidence.

Identifiers

PMID40124282
PMCPMC11918603

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.