Evidence map›Paper›PMID 40123678›Full record

ArticleJournal of experimental orthopaedics2025

Lower button-cortex distance and lower revision rates with adjustable-loop compared to fixed-loop cortical suspension devices for anterior cruciate ligament reconstruction.

Ron Gilat, Amit Gilad, Ilan Y Mitchnik, Yoav Comay, Assaf Moriah, Gabriel Agar, Yiftah Beer, Dror Lindner

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ron GilatDepartment of Orthopaedic Surgery Maimonides Medical Center New York New York USA.
Amit GiladDepartment of Orthopaedic Surgery Shamir Assaf Harofeh Medical Center Be'er Ya'akov Israel.ORCID 0009-0005-8091-3823
Ilan Y MitchnikDepartment of Orthopaedic Surgery Shamir Assaf Harofeh Medical Center Be'er Ya'akov Israel.
Yoav ComayDepartment of Orthopaedic Surgery Shamir Assaf Harofeh Medical Center Be'er Ya'akov Israel.
Assaf MoriahDepartment of Orthopaedic Surgery Shamir Assaf Harofeh Medical Center Be'er Ya'akov Israel.
Gabriel AgarDepartment of Orthopaedic Surgery Shamir Assaf Harofeh Medical Center Be'er Ya'akov Israel.
Yiftah BeerDepartment of Orthopaedic Surgery Shamir Assaf Harofeh Medical Center Be'er Ya'akov Israel.
Dror LindnerDepartment of Orthopaedic Surgery Shamir Assaf Harofeh Medical Center Be'er Ya'akov Israel.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To compare button position following femoral fixation of an anterior cruciate ligament (ACL) graft using fixed-loop cortical suspension device vs. an adjustable-loop device. Subsequently, to assess the association of button position-related factors and revision ACL reconstruction. Methods: This was a retrospective cohort study of consecutive patients undergoing ACL reconstruction using fixed-loop (Endobutton CL) and adjustable-loop cortical suspension device (Ultrabutton) for femoral fixation in a single institution between 2009 and 2022. Demographic and operative characteristics were recorded. To assess soft tissue interposition the distance between the button and the lateral femoral condyle (LFC) was measured on X-rays made on the first post-operative day. Other measurements included button angle, relative position (anterior/middle/posterior), and button migration (assessed using most recent X-rays). Results: Overall, 244 patients were included in the study. 59% of patients in the fixed-loop group and 41% in the adjustable-loop group. Hamstrings autograft was utilised most commonly (91%), while the rest of the procedures included allografts. A significantly shorter button distance from the LFC was noted in the post-operative Antero-posterior (AP) X-ray of the adjustable-loop button, 0.44 ± 0.52 mm versus 0.72 ± 0.84 mm, respectively ( Conclusions: Adjustable-loop cortical suspension devices for femoral fixation of an ACL reconstruction were associated with lower revision rates and a lower button-LFC distance when compared to fixed-loop devices. Level of Evidence: Level III, retrospective comparative cohort study.

Indexed as

ACL reconstructionadjustable‐loopbuttoncortical suspension devicefixed‐loop

Identifiers

PMID40123678
PMCPMC11928874

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.