ArticleEuropean radiology experimental2025

Photon-counting versus energy-integrating CT of abdomen-pelvis: a phantom study on the potential for reducing iodine contrast media.

Djamel Dabli, Maxime Pastor, Sebastian Faby, Julien Erath, Cédric Croisille, Fabricio Pereira, Jean-Paul Beregi, Joël Greffier

Abstract readComparative Study
In one paragraph

Article in European radiology experimental, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Djamel DabliDepartment of medical imaging, CHU Nîmes, Univ Montpellier, Nîmes Medical Imaging Group, UR UM103 IMAGINE, Nîmes, France. Djamel.dabli@chu-nimes.fr.ORCID http://orcid.org/0000-0003-1003-1196
Maxime PastorDepartment of medical imaging, CHU Nîmes, Univ Montpellier, Nîmes Medical Imaging Group, UR UM103 IMAGINE, Nîmes, France.
Sebastian FabyDepartment of Computed Tomography, Siemens Healthineers AG, Forchheim, Germany.
Julien ErathDepartment of Computed Tomography, Siemens Healthineers AG, Forchheim, Germany.
Cédric CroisilleDepartment of Computed Tomography, Siemens Healthineers AG, Forchheim, Germany.
Fabricio PereiraMIPA, University of Nîmes, Nîmes, France.
Jean-Paul BeregiDepartment of medical imaging, CHU Nîmes, Univ Montpellier, Nîmes Medical Imaging Group, UR UM103 IMAGINE, Nîmes, France.
Joël GreffierDepartment of medical imaging, CHU Nîmes, Univ Montpellier, Nîmes Medical Imaging Group, UR UM103 IMAGINE, Nîmes, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo assess the potential of virtual monoenergetic images (VMIs) on a photon-counting computed tomography (PCCT) for reducing the amount of injected iodine contrast media compared to an energy-integrating CT (EICT).

methodsA multienergy phantom was scanned with a PCCT and EICT at 11 mGy with abdomen-pelvis examination parameters. VMIs were generated at 40 keV, 50 keV, 60 keV, and 70 keV. For all VMIs, the contrast-to-noise ratio (CNR) of iodine inserts with concentrations of 1 mg/mL, 2 mg/mL, 5 mg/mL, 10 mg/mL, and 15 mg/mL was calculated by dividing the signal difference between HU in iodine inserts versus solid water by the noise value assessed on solid water. The potential reduction in iodine media was calculated by the rate of reduction in iodine concentration with PCCT while maintaining the same CNR obtained with EICT for the reference concentration.

resultsSignificantly higher CNR values were found with PCCT at all VMI energy levels for iodine concentrations above 1 mg/mL. The highest reduction was observed at 40 keV, with a value of 48.9 ± 1.6% (mean ± standard deviation). It decreased as the energy level increased, by 38.5 ± 0.5%, and 30.8 ± 0.8% for 50 and 60 keV, respectively. For 70 keV, the potential reduction of 24.4 ± 1.1% was found for iodine concentrations above 1 mg/mL. This reduction reached 57 ± 2.3% at 40 keV with PCCT compared to 60 keV with EICT.

conclusionFor abdomen-pelvis protocols, the use of VMIs with PCCT significantly improved the CNR of iodine, offering the potential to reduce the required contrast medium. RELEVANCE STATEMENT: The use of VMIs with PCCT may reduce the quantity of iodine contrast medium to be injected compared with EICT, limiting costs, the risk of adverse effects, and the amount of contrast agent released into the wastewater. KEY POINTS: PCCT improves the image quality of VMIs. PCCT offers the potential for reducing the amount of injected contrast medium. PCCT potential for reducing the injected contrast medium depends on energy level.

Indexed as

Contrast MediaIodinePelvisPhotonsRadiography, AbdominalTomography, X-Ray ComputedAbdomenHumansPhantoms, ImagingSignal-To-Noise RatioContrast MediaIodineAbdomenContrast mediaIodine compoundsPelvisTomography (x-ray computed)

Identifiers

PMID40121590
PMCPMC11930902

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.