Evidence map›Paper›PMID 40119893›Full record

ArticleChild's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery2025

Maintenance of construct integrity with subaxial cervical pedicle screws when crossing the cervicothoracic junction in complex pediatric deformity: an international multicenter study.

David B Kurland, Ritt R Givens, Alondra Concepción-González, Alexander Eremiev, Yosef Dastagirzada, Nikita Alexiades, Benjamin D Roye, Michael G Vitale, Richard C E Anderson, Pediatric Spine Study Group

Abstract readMulticenter Study
PubMed Publisher
In one paragraph

Article in Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

David B KurlandDepartment of Neurological Surgery, Hassenfeld Children'S Hospital, NYU Langone Health, NY 462 1st Avenue, Suite 7S4, New York, NY , 10016, USA.
Ritt R GivensDivision of Pediatric Orthopaedic Surgery, Department of Orthopaedic Surgery, Columbia University Irving Medical Center, New York, NY, USA.
Alondra Concepción-GonzálezDivision of Pediatric Orthopaedic Surgery, Department of Orthopaedic Surgery, Columbia University Irving Medical Center, New York, NY, USA.
Alexander EremievDepartment of Neurological Surgery, Hassenfeld Children'S Hospital, NYU Langone Health, NY 462 1st Avenue, Suite 7S4, New York, NY , 10016, USA.
Yosef DastagirzadaDepartment of Neurological Surgery, Hassenfeld Children'S Hospital, NYU Langone Health, NY 462 1st Avenue, Suite 7S4, New York, NY , 10016, USA.
Nikita AlexiadesDepartment of Neurological Surgery, University of Arizona - Phoenix, Phoenix, AZ, USA.
Benjamin D RoyeDivision of Pediatric Orthopaedic Surgery, Department of Orthopaedic Surgery, Columbia University Irving Medical Center, New York, NY, USA.
Michael G VitaleDivision of Pediatric Orthopaedic Surgery, Department of Orthopaedic Surgery, Columbia University Irving Medical Center, New York, NY, USA.
Richard C E AndersonDepartment of Neurological Surgery, Hassenfeld Children'S Hospital, NYU Langone Health, NY 462 1st Avenue, Suite 7S4, New York, NY , 10016, USA. richard.anderson@nyulangone.org.
Pediatric Spine Study Group

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveIn cases of complex pediatric spinal deformity, posterior spinal instrumentation crossing the cervicothoracic junction (CTJ) may be required. This is most frequently encountered for revision surgery to address proximal junctional kyphosis (PJK). In the cervical spine, lateral mass screws are most commonly used, although they may result in biomechanically weak proximal constructs and predispose to instrumentation failure. The use of supplemental anterior constructs has recently been reported with promising results, but this necessitates an additional surgical procedure. Subaxial cervical pedicle screws can provide good biomechanical fixation without the need for an anterior approach, but outcome data have been very limited. The purpose of this study was to assess radiographic and clinical outcomes at two years in pediatric patients who have undergone posterior spinal instrumentation and fusion (PSIF) crossing the CTJ using subaxial cervical spine pedicle screws.

methodsThe Pediatric Spine Study Group (PSSG) registry was queried to identify patients ≤ 21 years old who underwent PSIF crossing the CTJ with two-year minimum clinical and radiographic follow-up. Patients were excluded if they had a history of anterior stabilization or if their fusion construct with subaxial pedicle screws started below C6. Clinical, surgical, and radiographic parameters were assessed, and measurements were compared statistically.

resultsThen, 8 patients (6 female and 2 male) met inclusion criteria, with a mean age at surgery of 11.2 ± 3.3 years. All patients underwent PSIF crossing the CTJ (mean levels fused 15.6 ± 6.6). The mean density of subaxial cervical pedicle screws was 61.9% ± 27.8 (range 28.5 to 100%). The major coronal curve averaged 54.7° ± 19.6 preoperatively and 34.5° ± 13.6 postoperatively (41.5% ± 26.5 correction; p = 0.03). The average major sagittal curve was 55.9° ± 20.6 preoperatively and 29.6° ± 9.6 (44.2% ± 18.0 correction; p = 0.01) postoperatively. There were no major intraoperative or postoperative complications. Deformity parameters remained stable without radiographic evidence of PJK in 8/8 patients at minimum 2-year follow-up.

conclusionsIn this small preliminary international series of pediatric patients with spinal deformity, the inclusion of subaxial cervical pedicle screws in constructs that span the cervicothoracic junction resulted in good clinical and radiographic outcomes without major complications. Subaxial cervical spine pedicle screws provide enhanced biomechanical stability and may eliminate the need for additional anterior support in pediatric patients.

Indexed as

Cervical VertebraeKyphosisPedicle ScrewsSpinal FusionThoracic VertebraeAdolescentChildChild, PreschoolFemaleFollow-Up StudiesHumansMaleRetrospective StudiesTreatment OutcomeYoung AdultCervicothoracic junctionPediatric spinal deformitySpinal instrumentationSubaxial pedicle screws

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.