Endovascular neural stimulation with platinum and platinum black modified electrodes.

Alexander R Harris, Marko Ruslim, Huakun Xin, Zhiyi Shen, JingYang Liu, Tom Spencer, David Garrett, David B Grayden, Sam E John

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Alexander R HarrisDepartment of Biomedical Engineering, University of Melbourne, Melbourne, 3010, Australia. alexrharris@gmail.com.
Marko RuslimDepartment of Biomedical Engineering, University of Melbourne, Melbourne, 3010, Australia.
Huakun XinDepartment of Biomedical Engineering, University of Melbourne, Melbourne, 3010, Australia.
Zhiyi ShenDepartment of Biomedical Engineering, University of Melbourne, Melbourne, 3010, Australia.
JingYang LiuDepartment of Biomedical Engineering, University of Melbourne, Melbourne, 3010, Australia.
Tom SpencerDepartment of Biomedical Engineering, University of Melbourne, Melbourne, 3010, Australia.
David GarrettSchool of Engineering, RMIT University, Melbourne, VIC, 3001, Australia.
David B GraydenDepartment of Biomedical Engineering, University of Melbourne, Melbourne, 3010, Australia.
Sam E JohnDepartment of Biomedical Engineering, University of Melbourne, Melbourne, 3010, Australia. sam.john@unimelb.edu.au.

Funding

National Health and Medical Research Council 1158912
6 · The paper itself

Abstract

Recent work has shown the ability to record neural behaviour in pre-clinical studies from an endovascular location for over a year. Previous work on stimulating neural tissue from an endovascular location has also shown motor-evoked responses in sheep. However, endovascular stimulation requires high currents and can result in electrode degradation. This study aimed to modify an endovascular electrode to increase its charge injection capacity for efficacious neural stimulation. The platinum endovascular electrode was modified with platinum black and characterised by electrochemical and microscopic techniques. The stability of the electrode coating was assessed after a 7-day continuous stimulation paradigm. Modelling of the neural activating function was performed for central and peripheral neural anatomy with both electrode materials. Platinum black coatings had a substantially larger electroactive area than uncoated platinum. This resulted in increased electrode admittance, charge storage capacity and charge injection capacity while reducing the total impedance at 10 Hz and polarisation voltage. The coated electrode was comparatively more electrochemically stable than uncoated platinum following the 7-day continuous stimulation protocol. Modelling of the neural activating function indicated a substantial increase in the electrode-neuron distance which could be safely stimulated using platinum black coated electrodes. By comparison of electrochemical response with neural modelling, we have demonstrated the feasibility of safe stimulation of neural tissue using an endovascular neural interface, opening the possibility of a new, minimally invasive neural stimulation paradigm.

Indexed as

Electric StimulationNeuronsPlatinumAnimalsElectrodesElectrodes, ImplantedSheepPlatinumCharge transfer mechanismChronopotentiometric voltage transientsEndovascular neural interfacePlatinum blackStent-electrode array

Identifiers