Transcatheter arterial and venous embolisation with α-hexyl cyanoacrylate MagicGlue®: short-term safety and efficacy outcomes.

Hamza Sawalha, Olivier Chevallier, Mohamed Fouad, Taninokuchi Tomassini Makoto, Comby Pierre-Olivier, Ludwig Serge Aho-Glele, Romaric Loffroy

Abstract read
In one paragraph

Article in CVIR endovascular, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hamza SawalhaDepartment of Vascular and Interventional Radiology, Image-Guided Therapy Center, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21000, Dijon, France.
Olivier ChevallierDepartment of Vascular and Interventional Radiology, Image-Guided Therapy Center, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21000, Dijon, France.
Mohamed FouadDepartment of Vascular and Interventional Radiology, Image-Guided Therapy Center, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21000, Dijon, France.
Taninokuchi Tomassini MakotoDepartment of Vascular and Interventional Radiology, Image-Guided Therapy Center, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21000, Dijon, France.
Comby Pierre-OlivierDepartment of Emergency Radiology and Neuroradiology, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21000, Dijon, France.
Ludwig Serge Aho-GleleDepartment of Epidemiology, Statistics and Clinical Research, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21000, Dijon, France.
Romaric LoffroyDepartment of Vascular and Interventional Radiology, Image-Guided Therapy Center, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21000, Dijon, France. romaric.loffroy@chu-dijon.fr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeOur purpose was to assess the feasibility and the short-term safety and efficacy outcomes of a wide range of transcatheter arterial and venous embolisation procedures done using α-hexyl-cyanoacrylate (AHCA)-MagicGlue® in patients with bleeding and non-bleeding disorders.

methodsThis single-centre retrospective study included consecutive patients who underwent emergent or planned AHCA-MagicGlue® transcatheter embolisation between February 2019 and September 2023. Technical success, clinical success, 30-day mortality, and complication rates were evaluated.

resultsWe included 101 patients with a mean age of 49.9 ± 20.5 years who underwent arterial (n = 43, 42.6%) or venous (n = 58, 57.4%) embolisation for bleeding (n = 16, 15.8%) or other reasons (n = 85, 84.2%). The technical success rate was 100%. After a mean follow-up of 2.2 months, the clinical success rate was 94% in patients with bleeding and 95% in other patients; 1 patient died of multi-organ failure unrelated to the procedure. In the 22 patients with prostatic artery embolisation, statistically significant improvements were recorded at 3 months versus baseline for the International Prostate Symptoms Score (IPSS) (10.0 ± 5.8 vs. 20.8 ± 7.3, p = 0.001), IPSS quality-of-life score (2.0 ± 1.4 vs. 5.0 ± 1.0; p = 0.001), and prostate volume (67.8 ± 38.0 mL vs. 96.7 ± 47.4 mL, p = 0.001). Adverse events occurred in 11 (10.9%) patients and were major in 4 and minor in 7 patients.

conclusionsMagicGlue® transcatheter arterial and venous embolisation is feasible, effective, and safe for bleeding and non-bleeding conditions across a broad range of anatomic sites.

Indexed as

ArteryCyanoacrylateEmbolisationOutcomesVein

Identifiers

PMID40111639
PMCPMC11926286

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.