Evidence map›Paper›PMID 40111513›Full record

ArticleArchives of orthopaedic and trauma surgery2025

The incidence of radiolucent lines in cemented attune total knee arthroplasty- a retrospective clinical and radiological study.

Reza Sorbi, Tilman Walker, Timo A Nees, Tobias Renkawitz, Babak Moradi, Tobias Reiner

Erratum issuedAbstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Reza SorbiDepartment of Orthopaedics and Trauma Surgery, University Hospital of Schleswig-Holstein, Campus Kiel, Heidelberg, Germany.
Tilman WalkerDepartment of Orthopaedics, Heidelberg University Hospital, Heidelberg, Germany.
Timo A NeesDepartment of Orthopaedics, Heidelberg University Hospital, Heidelberg, Germany.
Tobias RenkawitzDepartment of Orthopaedics, Heidelberg University Hospital, Heidelberg, Germany.
Babak Moradi *Department of Orthopaedics and Trauma Surgery, University Hospital of Schleswig-Holstein, Campus Kiel, Heidelberg, Germany.
Tobias Reiner *Department of Orthopaedics, Heidelberg University Hospital, Heidelberg, Germany. tobias.reiner@med.uni-heidelberg.de.ORCID http://orcid.org/0000-0003-4563-6718

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe Attune total knee arthroplasty (TKA) system was introduced with the goal to improve clinical outcome, patient satisfaction and implant survival. The aim of the present study was to investigate the clinical and radiological outcome of the cemented Attune knee and to assess the rate of radiolucent lines (RLL) at a median follow-up of 4 years. MATERIALS AND

methodsIn this single-center cohort study, we retrospectively evaluated the clinical and radiological results of 165 consecutive patients following cemented TKA with the original design of the Attune knee at a minimum follow-up of two years. Postoperative radiographs were assessed for RLL and clinical outcome was measured using patient reported outcome scores.

resultsA total of 115 patients (127 knees) were available for assessment at a mean follow-up of 47.8 ± 12.9 months. The overall incidence of femoral and tibial RLL was 24% and 26%, respectively. Of the original cohort, two patients had to be revised during the course of the study, resulting in a survival rate of 98.9% at two years with the endpoint "revision for any reason". Clinical outcome scores improved significantly up to the latest follow-up.

conclusionsThe findings of this study demonstrated good clinical results with significant improvement in pain and knee function and acceptable revision rates at a median follow-up of 4 years. However, a high incidence of periprosthetic RLL was seen in this cohort. No implant showed signs of component loosening, but patients with RLL should be monitored closely and future studies with longer follow-up durations are necessary to investigate the influence of these radiolucencies on the long-term performance of this knee system.

Indexed as

Arthroplasty, Replacement, KneeKnee JointKnee ProsthesisPostoperative ComplicationsAgedAged, 80 and overBone CementsFemaleFollow-Up StudiesHumansIncidenceMaleMiddle AgedProsthesis DesignProsthesis FailureRadiographyBone CementsAseptic looseningAttunePatient reported outcome measuresPROMRadiolucent linesTkaTotal knee replacement

Identifiers

PMID40111513
PMCPMC11926027

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.