ArticlePediatric radiology2025
Photon-counting CT yields superior abdominopelvic image quality at lower radiation and iodinated contrast doses.
Article in Pediatric radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Radiation dose and objective image quality of photon-counting detector computed tomography in pediatric imaging: a systematic review and meta-analysis.Pediatric radiology · 2026Pooled it
- Next-gen paediatric imaging: ultra-low dose chest photon-counting CT approaching chest radiograph doses.European radiology experimental · 2026Article
- Understanding Photon-Counting CT: Physics, Detector Technology, and Image Reconstructions.Sensors (Basel, Switzerland) · 2026Review
- Reduction of iodinated contrast waste, cost, and greenhouse gas emissions using imaging bulk packaging in a pediatric hospital.Pediatric radiology · 2026Article
- Seeing the invisible: practical strategies to maximize the clinical impact of photon-counting CT in abdominal imaging.Abdominal radiology (New York) · 2026Review
- Photon-counting detector of the ophthalmic artery: impact of virtual monoenergetic levels, reconstruction kernel, and quantum iterative reconstruction (QIR) on image quality.Quantitative imaging in medicine and surgery · 2026Article
- Balancing radiation dose and image quality in infants on photon-counting CT for pediatric cardiac imaging: comparing 70 kV and 120 kV protocols.Pediatric radiology · 2026Article
- Photon-counting detector CT in oncology: a new era of cancer imaging.Insights into imaging · 2026Review
- Article
- Pediatric photon-counting chest CT enables iodinated contrast dose reduction with preserved image quality.Pediatric radiology · 2025Observational
- Advancements in Acute Pulmonary Embolism Diagnosis and Treatment: A Narrative Review of Emerging Imaging Techniques and Intravascular Interventions.Journal of cardiovascular development and disease · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPhoton-counting detector (PCD) computed tomography (CT) has been shown to provide better image quality at lower radiation and intravenous contrast doses than energy-integrating detector (EID) CT in adult patients. There is limited data on these benefits for the pediatric population especially for abdominopelvic CT examinations.
objectiveThis study examines a reduced weight-based iodinated contrast dosing strategy in pediatric abdominopelvic CT on a PCD-CT system compared to standard dosing protocols on EID-CT using 1 mL/kg and 2 mL/kg, respectively. Image quality is assessed using both quantitative and qualitative measures. We also compare the radiation dose profile between the two PCD-CT and EID-CT cohorts. MATERIALS AND
methodsThis HIPAA-compliant, IRB-approved, retrospective study included pediatric patients (≤18 years of age) who underwent contrast-enhanced CT examinations of the abdomen and pelvis for routine clinical care (01/2022 - 01/2023) in the portal-venous phase on a PCD-CT (NAEOTOM Alpha; Siemens Healthineers). Inclusion criteria included a similar prior examination within 12-months on a dual-source EID-CT scanner from the same vendor. All PCD-CT and EID-CT scans were acquired using weight-based dosing for intravenous contrast media, 1 mL/kg and 2 mL/kg, respectively, based on institutional protocols. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were measured in the aorta, portal vein, liver parenchyma, and skeletal muscle. Three pediatric radiologists qualitatively evaluated each scan for overall image quality, noise, and contrast on a scale of 0-100. Confidence in small structure detection (common bile duct) was also rated on a scale of 0-3. Radiation doses (size-specific dose estimate (SSDE)) were calculated. Statistical analysis included paired t-tests and a mixed linear effects model to account for patient age, sex, and X-ray tube voltage. A P<0.05 indicated statistical significance.
resultsA total of 49 patients were included (24 female; mean [SD] age 9.9 [6.3] years, range 0.6-18 years). Compared to EID-CT, PCD-CT had a higher mean SNR in the portal vein (23.4 [SD=9.3] vs 17.2 [SD=7.4], P<0.001), aorta (23.4 [SD=11.6] vs 17.7 [10.1], P=0.017), hepatic parenchyma (15.2 [SD=5.6] vs 13.2 [5.1], P=0.016), and skeletal muscle (5.7 [SD=3.1] vs 4.5 [SD=3.1], P=0.01). Compared to EID-CT, PCD-CT also had a higher mean CNR in the portal vein (27.5 [SD=9.6] vs 22.1 [SD=21.1], P=0.003), aorta (27.3 [SD=9.6] vs 22.3 [SD=11.8], P=0.004), hepatic parenchyma (20 [SD=6.9] vs 16.9 [SD=8.5], P=0.013), and skeletal muscle (14.6 [4.9] vs 12.1 [5.6], P=0.008). Overall image quality, image noise, and small structure detection confidence scores were higher on PCD-CT than EID-CT (P=0.037, P<0.001, and P=0.006, respectively). Mean SSDE for PCD-CT was lower than EID-CT (9.1 mGy [SD=4.3] vs 11 mGy [5.9], P=0.012).
conclusionCompared with EID-CT, contrast-enhanced pediatric abdominopelvic CT offers improved subjective and objective image quality, even at lower radiation doses and reduced intravenous contrast medium volumes.
Indexed as
Identifiers
40111456What OpenQuestion holds