Evidence map›Paper›PMID 40108760›Full record

ArticleBiotechnology and applied biochemistry2025

Selection of DNA Aptamers Against Parathyroid Hormone for Electrochemical Impedimetric Biosensor System Development.

Reza Didarian, Saharnaz Bargh, Almina Gülerman, Veli Cengiz Özalp, Özcan Erel, Nimet Yildirim-Tirgil

Abstract read
In one paragraph

Article in Biotechnology and applied biochemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Reza DidarianDepartment of Biomedical Engineering, Ankara Yıldırım Beyazıt University, Ankara, Türkiye.
Saharnaz BarghDepartment of Radiopharmacy, Faculty of Pharmacy, Hacettepe University, Ankara, Türkiye.
Almina GülermanDepartment of Metallurgy and Materials Engineering, Ankara Yıldırım Beyazıt University, Ankara, Türkiye.
Veli Cengiz ÖzalpDepartment of Medical Biology, School of Medicine, Atılım University, Ankara, Türkiye.
Özcan ErelDepartment of Biovchemistry, Faculty of Medicine, Ankara Yıldırım Beyazıt University, Ankara, Türkiye.
Nimet Yildirim-TirgilDepartment of Biomedical Engineering, Ankara Yıldırım Beyazıt University, Ankara, Türkiye.

Funding

Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
6 · The paper itself

Abstract

This work presents the pioneering development of an aptamer-based electrochemical biosensor for real-time monitoring of parathyroid hormone (PTH) levels, with a focus on intraoperative assessment during parathyroid surgery. It introduces, for the first time, the selection and characterization of aptamers targeting distinct segments of the PTH peptide. The study demonstrates the feasibility and efficacy of the biosensing platform through a precisely designed experimental framework, including SELEX-based aptamer selection, aptamer-peptide interaction analysis, and biosensor fabrication. The SELEX process yields aptamers with notable binding affinities to different fragments of PTH, with the PTH (53-84) aptamer showing particularly sensitive binding to the hormone's C terminus, allowing for precise PTH analysis. Electrochemical characterization reveals significant changes in electrochemical impedance spectroscopy (EIS) signals upon exposure to varying PTH concentrations, highlighting the sensor's sensitivity and selectivity. The increase in charge transfer resistance (Rct) values with rising PTH concentrations underscores the biosensor's capability to detect PTH-induced structural changes, validating its potential for accurate measurement. The biosensor shows remarkable selectivity in the presence of common interferents in serum samples, ensuring precise PTH detection. Stability assessments over a 45-day storage period demonstrate the biosensor's robustness and long-term reliability, affirming its practical suitability. In summary, the developed aptamer-based biosensor represents a promising tool for sensitive and selective PTH detection, with potential applications in biomedical research and clinical diagnostics, particularly for intraoperative PTH analysis during parathyroidectomy. Continued research and optimization efforts hold promise for enhancing its performance and expanding its utility in diverse healthcare settings.

Indexed as

Aptamers, NucleotideBiosensing TechniquesElectrochemical TechniquesParathyroid HormoneSELEX Aptamer TechniqueDielectric SpectroscopyHumansAptamers, NucleotideParathyroid Hormoneaptamerelectrochemical detectionelectrochemical impedance spectroscopy (EIS)impedimetric biosensorparathyroid hormone (PTH)SELEX

Identifiers

PMID40108760
PMCPMC12529457

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.