Evidence map›Paper›PMID 40104902›Full record

ReviewZhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences2025

[Impact of elevated arterial blood pressure on bioprosthetic valve calcification and failure after transcatheter aortic valve replacement].

Wenjing Sheng, Qifeng Zhu, Hanyi Dai, Dao Zhou, Xianbao Liu

Abstract readReviewEnglish Abstract
In one paragraph

Review in Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Wenjing ShengDepartment of Cardiology, the Second Affiliated Hospital, Zhejiang University School of Medicine, State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China. wenjingsheng11414@163.com.
Qifeng ZhuDepartment of Cardiology, the Second Affiliated Hospital, Zhejiang University School of Medicine, State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China.
Hanyi DaiDepartment of Cardiology, the Second Affiliated Hospital, Zhejiang University School of Medicine, State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China.
Dao ZhouDepartment of Cardiology, the Second Affiliated Hospital, Zhejiang University School of Medicine, State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China.
Xianbao LiuDepartment of Cardiology, the Second Affiliated Hospital, Zhejiang University School of Medicine, State Key Laboratory of Transvascular Implantation Devices, Hangzhou 310009, China. liuxb@zju.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Transcatheter aortic valve replacement (TAVR) has emerged as the standard treatment for severe aortic stenosis, demonstrating comparable efficacy to traditional surgery in low and intermediate-risk patients. However, the bioprosthetic valves utilized in TAVR have a limited lifespan, and bioprosthetic valve failure, including calcification, rupture or infection may develop, leading to poor clinical outcomes. Elevated blood pressure has been identified as a key factor in aortic valve calcification, and its role in bioprosthetic valve failure is gaining increasing attention. Hypertension may accelerate the calcification process and exacerbate valve failure due to increased mechanical stress on the valve, activation of the renin-angiotensin system, and enhanced thrombus formation. Furthermore, elevated blood pressure interacts with prosthesis mismatch and paravalvular leak, jointly affecting valve durability. This review explores the impact of elevated blood pressure on bioprosthetic valve calcification and failure after TAVR, and emphasizes the importance of blood pressure control, optimized preoperative assessment, and appropriate valve selection in reducing valve failures.

Indexed as

Aortic ValveAortic Valve StenosisBioprosthesisCalcinosisHeart Valve ProsthesisHypertensionProsthesis FailureTranscatheter Aortic Valve ReplacementHumansBioprosthetic valve failureBioprosthetic valves calcificationHigh artery blood pressureReviewTrans-catheter aortic valve replacement

Identifiers

PMID40104902
PMCPMC12062944

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.