Evidence map›Paper›PMID 40104657›Full record

ArticleReports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology2024

Can the daily position of bolus material influence radiotherapy treatment?

Ghizela A-M Salagean, Zoltán Bálint, Philip Poortmans, Daniel Portik

Abstract read
In one paragraph

Article in Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Developing a novel immobilization method for breast cancer radiation therapy with tissue expander.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2026
    Article
  2. Chronic radiation-induced dermatitis: what is new in 2024? A narrative review.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2026
    Review
  3. Custom-made, 3D-printed bolus cap for a case of scalp metastasis: A single-institution study.Technical innovations & patient support in radiation oncology · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ghizela A-M SalageanFaculty of Physics, Babes Bolyai University Cluj-Napoca, Romania.
Zoltán BálintFaculty of Physics, Babes Bolyai University Cluj-Napoca, Romania.
Philip PoortmansDepartment of Radiation Oncology, Iridium Netwerk, Antwerp, Belgium.
Daniel PortikTopMed Medical Centre, Targu Mures, Romania.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Daily bolus positioning implies a high degree of variability, which can affect the dose distribution within the planning target volume (PTV) and the organs at risk (OAR). We carried out a retrospective study to evaluate bolus positioning in patients with breast cancer. Materials and methods: We evaluated 7 cases with left and 5 cases with right chest-wall with comprehensive nodal region irradiation in which bolus material was used to obtain better skin surface coverage. The bolus positioning on the daily cone-beam computed tomography (CBCT) images was compared to the reference image from the treatment planning system. Deviations from the reference position of the bolus were categorized as positive shifts (PosS) or negative shifts (NegS), depending on the material's overlapping with its planned position. Subsequently, a second plan was calculated using the information from the CBCT images for comparison with the original treatment plan. We performed a statistical and dosimetric analysis on the results. Results: For both the 95% dose coverage for the PTV for the chest wall and for the lymph node regions, about 2% variation between initial and recalculated plans was seen, with a shift of the hotspots' position in some cases. The average mean heart dose was 4.1 ± 0.3 Gy, whereas the values for PosS and NegS mean heart doses were 3.8 ± 0.4 Gy and 4.0 ± 0.6 Gy, respectively. In contrast to the original values for the ipsilateral lung V5 (57.1 ± 12.9%), V20 (30.2 ± 2.7%), and Dmean (15.0 ± 1.7 Gy), the values for PosS were 56.1 ± 4.2% for V5:, 30.1 ± 3.3% for V20, and 14.9 ± 1.2 Gy for Dmean while for NegS we obtained 56.9 ± 8.9% for V5, 30.0 ± 2.3% for V20, and 15.2 ± 1.8 Gy for Dmean. Conclusion: We observed dosimetric differences between the initial and given treatment plans depending on the position of the bolus for all cases, indifferent of the shift direction. Although the differences were not statistically significant, we identified a few specific instances where the variations might cause uncertainties regarding doses to the organs at risk (OAR). We suggest therefore that strategies for correct daily reproducibility of the bolus need to be implemented on a departmental level.

Indexed as

bolus materialbreast cancerpositioningradiotherapy

Identifiers

PMID40104657
PMCPMC11912895

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.