Evidence map›Paper›PMID 40104417›Full record

ArticleJournal of plastic and reconstructive surgery2024

Evaluating the Reliability of Three-dimensional Models Constructed Photogrammetry Software 3DF Zephyr by Measuring Joint Angles of Fingers: A Comparison to a Conventional Goniometer.

Keisuke Miyake

Abstract read
In one paragraph

Article in Journal of plastic and reconstructive surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Keisuke MiyakePlastic Surgery, Saiseikai Matsuyama Hospital, Matsuyama, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: Photogrammetry is a method of producing three-dimensional (3D) data from multiple photographs and videos. The purpose of this study was to evaluate the reliability of 3D hand models constructed using photogrammetry. Methods: The angles of the distal (DIP) and proximal (PIP) interphalangeal joints of the author's index finger were measured using a protractor goniometer. Five different blocks were used to stabilize the angles of the fingers. We collected 50 photographs and one video. Digital 3D models of the hand were constructed using 3DF Zephyr photogrammetry software. The angles of the DIP and PIP joints of the model were measured in virtual space. The angles obtained via the two methods were subjected to correlation analysis. Results: Eighty values (40 joints of 20 fingers; goniometer/3D model) were obtained. The maximum value obtained was 84° and the minimum was 33°. The average time required to take the original photographs of the model was 3 minutes, and that for the videos was 51 seconds. The average time required to construct a 3D image was 12 minutes. The greatest difference between the methods was 9° and the mean difference was 0.2°. The intraclass correlation coefficient (2,1) was 0.971. Conclusions: A high level of agreement was found between these angles. A 3D hand model constructed using photogrammetry is reproducible.

Indexed as

goniometerhandphotogrammetrythree-dimension

Identifiers

PMID40104417
PMCPMC11913006

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.