Evidence map›Paper›PMID 40103984›Full record

ArticleRSC advances2025

A high-performance reagent-less sensor based on copper(ii) phthalocyanines supported by multi-walled carbon nanotubes for phosphate detection.

Malak Talbi, Adiraju Anurag, Christoph Tegenkamp, Mounir Ben Ali, Olfa Kanoun

Abstract read
In one paragraph

Article in RSC advances, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Malak TalbiProfessorship Measurement and Sensor Technology, Technische Universität Chemnitz Reichenhainer Str. 70 09126 Chemnitz Germany malak.talbi@etit.tu-chemnitz.de adiraju.anurag@etit.tu-chemnitz.de olfa.kanoun@etit.tu-chemnitz.de.ORCID https://orcid.org/0000-0002-0825-0317
Adiraju AnuragProfessorship Measurement and Sensor Technology, Technische Universität Chemnitz Reichenhainer Str. 70 09126 Chemnitz Germany malak.talbi@etit.tu-chemnitz.de adiraju.anurag@etit.tu-chemnitz.de olfa.kanoun@etit.tu-chemnitz.de.
Christoph TegenkampAnalysis of Solid Surfaces, Institute for Physics, Chemnitz University of Technology 09107 Chemnitz Germany christoph.tegenkamp@physik.tu-chemnitz.de.ORCID https://orcid.org/0000-0003-0453-0765
Mounir Ben AliCRMN, Centre for Research on Microelectronics and Nanotechnology of Sousse, NANOMISENE Lab, University of Sousse LR16CRMN01 4050 Sousse Tunisia mounir.benali@issatso.rnu.tn.
Olfa KanounProfessorship Measurement and Sensor Technology, Technische Universität Chemnitz Reichenhainer Str. 70 09126 Chemnitz Germany malak.talbi@etit.tu-chemnitz.de adiraju.anurag@etit.tu-chemnitz.de olfa.kanoun@etit.tu-chemnitz.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Phosphate concentration is an important indicator of water quality, specifically for eutrophication levels in the presence of algae. Several analytical techniques have been proposed for phosphate monitoring, and most of them are based on indirect methods. In this study, we propose a new reagent-less direct method for the electrochemical detection of phosphate in aqueous solutions. For this, carbon screen printed electrodes (CSPE) were modified with copper(ii)-phthalocyanines (CuPc) that offer excellent oxidoreduction and electrocatalytic properties, together with chemically modified multiwalled carbon nanotubes (MWCNTs) to enhance the electrocatalytic performance of the sensor. We implemented two detection methods, which are electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV) to compare them. The developed sensor exhibits a remarkable detection limit of 1.15 μM in the range from 10 μM to 100 μM with voltammetry and 0.13 nM in the range from 0.001 μM to 100 μM with impedance, enabling accurate measurement of phosphate concentrations in water samples. Thus, EIS shows a better sensitivity towards phosphate reduction. Furthermore, the developed sensor shows good performance in the presence of possibly interfering species that usually coexist with phosphate ions, as well as the applicability of the sensor in real water samples (tap water and nutrient water from an aquaponic system) at a good recovery rate. The electrode's response is highly reproducible with a relative standard deviation lower than 10%.

Identifiers

PMID40103984
PMCPMC11912356

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.