ArticleAJOG global reports2025
Cervical elastography at 18 to 23 weeks to predict spontaneous preterm birth in individuals with a history of preterm birth.
Article in AJOG global reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Predictive performance of cervical elastography for preterm birth: A head-to-head network meta-analysis.World journal of radiology · 2026Article
- Cervical strain elastography improves mid-trimester prediction of spontaneous preterm birth beyond cervical length: a single-center cohort study.Frontiers in medicine · 2026Article
- Cervical Elastography as a Predictive Tool for Preterm Birth: A Systematic Review and Meta-analysis.Cureus · 2025Review
- Multi-parametric quantitative evaluation of murine cervical remodeling during pregnancy and postpartum.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIndividuals with a history of spontaneous preterm birth are at increased risk for recurrence in a subsequent pregnancy. Current methods used to predict those at highest risk are not precise. Cervical elastography is an investigational ultrasonographic technique that measures cervical tissue stiffness and may aid in identifying individuals at highest risk.
objectiveThis study aimed to assess the association between previously described cervical elastography measures-obtained using a semiautomatic application (E-cervix)-and preterm birth <37 weeks' gestation in a high-risk cohort with a history of spontaneous preterm birth. STUDY
designIndividuals with a singleton pregnancy between 18+0 and 23+6 weeks of gestation with a history of spontaneous preterm birth <37 weeks were prospectively enrolled. Exclusion criteria included the presence of a current cerclage or any uterine anomaly. The primary exposures were the E-cervix quantitative parameters (internal os stiffness, external os stiffness, internal-to-external os stiffness ratio, hardness ratio, and elasticity contrast index), which were measured at the time of enrollment. Transvaginal cervical length was also measured as an exposure to compare the current standard of care and accepted cutpoint of 25 mm alongside the E-cervix parameters. The primary outcome was preterm birth <37 weeks. The intra- and interrater reliability intraclass correlation coefficient for each parameter was calculated using a mixed-effects model. The area under the curve was derived from receiver operating characteristic curves to evaluate the association of each parameter with the primary outcome, and the optimal cutpoints for each continuous parameter were identified. Multivariable logistic regression was performed for the parameters that were either significant on univariate analysis or had an area under the curve of ≥0.6, using the calculated cutpoint to create a binary exposure and adjusting for gestational age at the earliest prior preterm birth, number of prior preterm births, and progesterone use. A sensitivity analysis was performed excluding medically indicated preterm birth.
resultsOf the enrolled 245 individuals with a history of spontaneous preterm birth, 69 (28%) had preterm birth <37 weeks. Intrarater and interrater reliability were good for all parameters (intrarater: 0.60-0.74; interrater: 0.62-0.71). In univariate analysis, only the internal-to-external os stiffness ratio was significantly associated with increased risk of preterm birth compared with no preterm birth (0.97±0.23 vs 0.90±0.20;
conclusionElastography with E-cervix technology can be reliably assessed in a cohort of women with prior preterm birth. The parameter most useful for predicting preterm birth was an internal-to-external os stiffness ratio ≥1.0, whereas cervical length <25 mm was not predictive in our cohort.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.