Evidence map›Paper›PMID 40103629›Full record

ArticleARYA atherosclerosis2024

Clinical performance and safety of the Vector® percutaneous transluminal coronary angioplasty balloon catheter: A single-arm, multicenter, retrospective post-marketing clinical study.

Preeti Vani, Arvind Patel, Kumar Abhishek, Kailash Goyal

Abstract read
In one paragraph

Article in ARYA atherosclerosis, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Preeti VaniMedical Division, Sahajanand Laser Technology Limited, A-8, G.I.D.C, Electronic Estate, Sec-25, Gandhinagar 382028, India.
Arvind PatelSahajanand Laser Technology Limited, A-8, G.I.D.C, Electronic Estate, Sec-25, Gandhinagar 382028, India.
Kumar AbhishekInterventional Cardiologist, Maharaja Agrasen Hospital, Fulbari Truck Terminus, Dist, Siliguri, West Bengal 734015, India.
Kailash GoyalInterventional Cardiologist, North Bengal Neuro Centre Multispeciality Hospital, Maghnad Saha Sarani, Ward 2, Pradhan Nagar, Siliguri, West Bengal, 734003, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe present post-marketing clinical study was conducted over a 12-month follow-up period to monitor the clinical outcomes of patients treated with the Vector® Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Catheter for the dilatation of coronary lesions. The semi-compliant balloon improves balloon-to-vessel wall apposition and minimizes balloon slippage during PTCA, which could reduce complications and improve clinical outcomes. This investigation aimed to assess the safety and effectiveness of the Vector® PTCA Balloon Catheter in real-world settings.

methodsA retrospective study was conducted to investigate the safety and efficacy of the Vector® PTCA Balloon Catheter in 125 patients who underwent pre-dilatation and post-dilatation. The primary outcome of the study was major adverse cardiac events (MACE), a composite endpoint encompassing target-lesion revascularization (TLR), cardiac death, and myocardial infarction (MI).

resultsThe Vector® PTCA Balloon Catheter has shown promising results in a small group of patients undergoing dilatation of normal and intricate coronary artery lesions, reflecting a 100% procedural success rate. The successful delivery to the target lesion, deployment, and subsequent retrieval of the device during the index procedure led to a 100% device success rate without any technical issues. A total of 3.2% (4) patients experienced MACE during the 12-month follow-up, with 1.6% (2) MI, 1.6% (2) TLR, and no cardiovascular deaths..

conclusionThis study demonstrated the favorable safety and reliability of the Vector® PTCA Balloon Catheter in patients with angina, MI, and a history of coronary artery disease in a real-world setting.

Indexed as

Balloon AngioplastyCoronary StenosisDilatationMajor Adverse Cardiac EventPercutaneous Coronary InterventionSemi-Compliant Balloon