Evidence map›Paper›PMID 40103609›Full record

ArticleJournal of mass spectrometry and advances in the clinical lab2025

Development and validation of a highly-sensitive, quantitative LC-MS/MS assay to evaluate plasma oxytocin.

E Grifnée, A Mackowiak, J Demeuse, M Schoumacher, L Huyghebaert, W Determe, T Dubrowski, P Massonnet, S Peeters, G Scantamburlo and 2 more

Abstract read
In one paragraph

Article in Journal of mass spectrometry and advances in the clinical lab, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

E GrifnéeDepartment of Clinical Chemistry, University Hospital of Liège, Belgium.
A MackowiakDepartment of Clinical Chemistry, University Hospital of Liège, Belgium.
J DemeuseDepartment of Clinical Chemistry, CIRM, University of Liège, Belgium.
M SchoumacherDepartment of Clinical Chemistry, CIRM, University of Liège, Belgium.
L HuyghebaertDepartment of Clinical Chemistry, University Hospital of Liège, Belgium.
W DetermeDepartment of Clinical Chemistry, CIRM, University of Liège, Belgium.
T DubrowskiDepartment of Clinical Chemistry, University Hospital of Liège, Belgium.
P MassonnetDepartment of Clinical Chemistry, University Hospital of Liège, Belgium.
S PeetersDepartment of Clinical Chemistry, University Hospital of Liège, Belgium.
G ScantamburloDepartment of Psychiatry, University Hospital of Liège, Belgium.
E CavalierDepartment of Clinical Chemistry, University Hospital of Liège, Belgium.
C Le GoffDepartment of Clinical Chemistry, University Hospital of Liège, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Oxytocin is a 9-amino acid peptide that serves as neuromodulator in the human central nervous system. This peptide is implicated in the regulation of diverse behaviors and plays a significant role in positive social interaction. Currently, oxytocin levels are measured using immunoassays. However, these methods have several limitations that can lead to false results and erroneous interpretation. Given the remarkably low endogenous level of oxytocin in human plasma (low ng/L levels), we developed and rigorously validated a novel and highly sensitive LC-MS/MS method for oxytocin quantification in plasma. Methods: Oxytocin was initially extracted using solid-phase extraction with an Oasis HLB 30 mg plate and then subjected to LC-MS/MS analysis. PBS-0.1 % BSA served as surrogate matrix for the preparation of validation samples and the calibration curve, ensuring no endogenous interference. The validation design followed the Clinical Laboratory Standards Institute guidelines. Precision, accuracy, and measurement uncertainty were determined using single-nested analysis of variance and e.noval software. Results: A lower limit of quantification of 1 ng/L was achieved. The method was validated for oxytocin concentrations ranging from 1 ng/L to 75 ng/L, with precision (coefficient of variation) below 10 %, accuracy ranging from 94 % to 108 %, and measurement uncertainty below 15 %. Conclusion: In this work, we developed and validated a highly sensitive LC-MS/MS method for the quantification of oxytocin in plasma. Our novel methodology is well-suited for clinical applications.

Indexed as

CLSI guidelinesLiquid chromatographyOxytocinPsychiatric disordersSolid phase extractionTandem mass spectrometry

Identifiers

PMID40103609
PMCPMC11919332

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.