Evidence map›Paper›PMID 40103471›Full record

ArticleCurrent medical imaging2025

Fetal Diagnostics using Vision Transformer for Enhanced Health and Severity Prediction in Ultrasound Imaging

Eshika Jain, Pratham Kaushik, Vinay Kukreja, Sakshi, Ayush Dogra, Bhawna Goyal

Abstract read
In one paragraph

Article in Current medical imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Eshika JainCenter for Research Impact & Outcome, Chitkara University Institute of Engineering and Technology, Chitkara University, Punjab, India.
Pratham KaushikCenter for Research Impact & Outcome, Chitkara University Institute of Engineering and Technology, Chitkara University, Punjab, India.
Vinay KukrejaCenter for Research Impact & Outcome, Chitkara University Institute of Engineering and Technology, Chitkara University, Punjab, India.
SakshiAmity Institute of Information Technology, Amity University, Noida, India.
Ayush DograCenter for Research Impact & Outcome, Chitkara University Institute of Engineering and Technology, Chitkara University, Punjab, India.
Bhawna GoyalDepartment of ECE and UCRD, Chandigarh University, Mohali, Punjab, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimThis research aims to develop and evaluate a novel health classification and severity detection system based on Vision Transformers (ViTs) for fetal ultrasound imagery. This contributes to improved precision in fetal health status detection and abnormalities with more accurate results than other traditional models.

backgroundAmidst the other imperatives of resource-deficient developing nations, mitigating neonatal mortality rates is a challenge that demands precisionbased solutions in the era of artificial intelligence. Though the advent of machine learning models has added an optimal dimension to deal with emerging complexity in fetal ultrasound imagery, there is a call to address the huge gap in the demanded precision for prediction than the existing interpretation.

objectiveThis research strives to formulate and access a novel health classification and severity detection system based on the implementation of the Vision Transformers frameworks. This pioneering investigation represents an unparalleled exploration into the efficacy of ViTs for discerning intricate patterns within fetal ultrasonographic imagery, facilitating precise categorization of fetal well-being and prognosticating the magnitude of potential anomalies. METHODOLOGY: A private and confidential dataset of 500 fetal ultrasound images has been collected from diverse hospitals. Each image has been annotated by radiologists according to two main labels: the health status of the fetus, which includes healthy, mild, moderate, or severe, and the severity of abnormalities as a continuous measure. At different levels, the dataset underwent pre-processing via distinct techniques. Then, the composite loss function Cross-Entropy has been deployed to train the optimized VIT model using the Adam algorithm.

resultsThe classification accuracy of the proposed model is 90% for detecting the severity with an F1-score of 0.87 and MAE of 0.30. The research ascertained that the model ViT evinced a superlative efficacy for the capturing of fine-grained spatial relations in ultrasound images to produce revolutionary predictions.

conclusionThese results emphasize that ViTs have the potential to revolutionize fetal health monitoring and will contribute significantly to reducing neonatal mortality by supplying clinicians with accurate and reliable predictions for early interventions. This work stands as a yardstick for further diagnostic applications using AI in fetal health care.

Indexed as

Machine LearningUltrasonography, PrenatalArtificial IntelligenceFemaleHumansPregnancySeverity of Illness IndexFetal anomaly detection.Fetal health classificationPrenatal diagnosisSeverity detectionTransformerUltrasound images

Identifiers

PMID40103471
PMCPMC13227578

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.