Evidence map›Paper›PMID 40102993›Full record

ArticleJournal of orthopaedic surgery and research2025

Robot milling system integrated design and finite element analysis of custom femoral prostheses.

Qi Wu, Pengju Yue, Siyu Yin, Wang Liu, Zhenjie Li, Renjie He

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Qi WuOrthopedic Surgery, The 82nd Hospital of People's Liberation Army, No. 100, Jiankang East Road, Qingjiangpu District, Huai'an, Jiangsu Province , 223001, China.
Pengju YueOrthopedic Surgery, The 82nd Hospital of People's Liberation Army, No. 100, Jiankang East Road, Qingjiangpu District, Huai'an, Jiangsu Province , 223001, China. yuepengju2024@163.com.
Siyu YinOrthopedic Surgery, The 82nd Hospital of People's Liberation Army, No. 100, Jiankang East Road, Qingjiangpu District, Huai'an, Jiangsu Province , 223001, China.
Wang LiuOrthopedic Surgery, The 82nd Hospital of People's Liberation Army, No. 100, Jiankang East Road, Qingjiangpu District, Huai'an, Jiangsu Province , 223001, China.
Zhenjie LiOrthopedic Surgery, The 82nd Hospital of People's Liberation Army, No. 100, Jiankang East Road, Qingjiangpu District, Huai'an, Jiangsu Province , 223001, China.
Renjie HeOrthopedic Surgery, The 82nd Hospital of People's Liberation Army, No. 100, Jiankang East Road, Qingjiangpu District, Huai'an, Jiangsu Province , 223001, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The long-term stability of cementless femoral prostheses is primarily affected by aseptic loosening, micromotion, and stress shielding, all of which are related to the force transfer of the prosthesis. These factors can compromise the osseointegration of the proximal prosthesis, leading to aseptic loosening within the femoral cavity. Due to the individual variability of the femur, the fit between the prosthesis and the femoral cavity during the design phase may differ from the fit achieved during the surgical procedure. Consequently, the force transfer of the prosthesis postoperatively may not align with the results obtained from finite element analysis conducted during the design phase, making it challenging to control the micromotion and stress shielding of the prosthesis. The design model of a custom femoral prosthesis is based on the CT reconstruction of the patient' femur. The fit of prosthesis within the femoral cavity during the design phase should match the fit during the surgical operation. Consequently, the results of finite element analysis conducted during the design phase can be used to control the force transfer of the prosthesis postoperatively. This approach helps to prevent improper micromotion and stress shielding of the proximal prosthesis, which can compromise the primary stability of the prosthesis within the femoral cavity, thereby facilitating the osseointegration of the proximal prosthesis.This paper proposes a novel technology that combines the design, finite element analysis, and manufacturing of custom prostheses. Specifically, a CAD/CAM/robot integration method is used to fabricate these prostheses. This innovative technology not only enhances the control of force transfer in custom prostheses but also reduces design and manufacture time while lowering costs. In conclusion, the finite element analysis of the custom prosthesis effectively manages force transfer, and the milling errors associated with the custom prosthesis are less than 1 mm.

Indexed as

Arthroplasty, Replacement, HipFemurFinite Element AnalysisHip ProsthesisProsthesis DesignRobotic Surgical ProceduresHumansCustom prosthesisDesign and manufactureFinite element analysisForce transferIntegration technology

Identifiers

PMID40102993
PMCPMC11921559

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.