Analysis of material composition and attenuation characteristics of anthropomorphic torso phantoms for dosimetry using dual energy CT technology.
Article in Physical and engineering sciences in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Scatter Removal in Photon-Counting Dual-Energy Chest X-Ray Imaging Using a Moving Block Method: A Simulation Phantom Study.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Anthropomorphic phantoms are often used to estimate organ absorbed doses. However, the material composition of these phantoms is not identical to that of the human body, which may cause errors in the measurement results. The purpose of this study was to analyze the material composition of several anthropomorphic torso phantoms using dual energy computed tomography (DECT), and to clarify the differences in attenuation characteristics among the phantoms. Anthropomorphic torso phantoms (ATOM, RANDO, and PBU-60) from different manufacturers were scanned with DECT. The target organs were lung, soft tissue, liver, bone, and bone surface, and a spectral Hounsfield unit curve (HU curve) was created from the relationship between energy and CT values. Ideal CT values were estimated from the mass attenuation coefficient and density proposed by the International Commission on Radiation Units and Measurements report 44 (ideal value) and compared with the values of each phantom. There were large differences in attenuation characteristics among the phantoms for soft tissue, liver, and bone. The respective ideal, ATOM, RANDO, and PBU-60 CT values of soft tissue were 59.82, 14.17, 34.22, and - 70.11 at 45 keV; and 53.13, 24.41, 3.97, and - 5.75 at 70 keV. The phantom closest to the ideal value may differ depending on the energy. Differences in HU curve and CT values indicate that some organs in the phantom have different material composition and attenuation characteristics to human tissues. When the phantoms available for dosimetry are limited, it is important to understand the attenuation characteristics of each phantom used.