ArticleAnnals of thoracic surgery short reports2025
Acute Clinical Adverse Outcomes Associated With the Cor-Knot.
Article in Annals of thoracic surgery short reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Recurrent STEMI After Surgical Aortic Valve Replacement.JACC. Case reports · 2025Article
- Acute clinical adverse events associated with the LUCAS chest compression system.Resuscitation plus · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Although an integral component of cardiac valve operations, manual knot tying has been linked with increased operative times and greater costs. The introduction of the Cor-Knot device (LSI Solutions) has eliminated hand-tied knots through an automatic titanium fastener system. However, adverse outcomes related to this device remain unknown. We thus used a nationally representative cohort to characterize adverse events of the Cor-Knot. Methods: All adverse events for the Cor-Knot from 2015-2023 were tabulated from the Manufacturer and User Facility Device Experience database. Reports were screened to assess incident type and complication. Device and patient complications were categorized and reported as proportions to further ascertain factors contributing to the development of adverse incidents. Results: Of an estimated 74 adverse events, the number of reported occurrences increased over the study period from 1 in 2015 to 13 in 2023. The greatest proportion of adverse events involved the Cor-Knot Mini (41.9%) or the Cor-Knot (37.4%), with malfunction representing the most frequent device incident (63.5%). Problems related to device usage (22.8%) or misfire (22.8%) constituted the most frequent complications after Cor-Knot usage. The most frequent complications included valve insufficiency (10.8%), presence of a foreign body (8.1%), or hemorrhage (2.7%). Conclusions: Of all reported adverse events, malfunction was most likely to occur due to misfire or device usage issues. Patient complications comprised valve insufficiency, foreign body presence, or hemorrhage. As adoption and utilization of the Cor-Knot increases, future work is necessary to ensure adequate device training and minimize the incidence of adverse events.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.