Evidence map›Paper›PMID 40097960›Full record

ArticleBMC pediatrics2025

Association between umbilical venous catheter‒related hepatic complications and tip position in neonates: a retrospective ultrasound-based analysis.

Baohui Wu, Dongqian Wu, Chao Wang, Xia Sun, Fei Dong, Ning Liu, Zhao Wang, Pengfei Li

Abstract read
In one paragraph

Article in BMC pediatrics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Baohui WuDepartment of Ultrasound, Harrison International Peace Hospital, Hengshui, 053000, China.
Dongqian WuDepartment of Ultrasound, Harrison International Peace Hospital, Hengshui, 053000, China.
Chao WangDepartment of Neonatology, Harrison International Peace Hospital, Hengshui, 053000, China.
Xia SunDepartment of Ultrasound, Harrison International Peace Hospital, Hengshui, 053000, China.
Fei DongDepartment of Neonatology, Harrison International Peace Hospital, Hengshui, 053000, China.
Ning LiuDepartment of Ultrasound, Harrison International Peace Hospital, Hengshui, 053000, China.
Zhao WangDepartment of Science & Education, Harrison International Peace Hospital, No. 180 Renmin Road, Hengshui, Hebei Province, 053000, China.
Pengfei LiDepartment of Science & Education, Harrison International Peace Hospital, No. 180 Renmin Road, Hengshui, Hebei Province, 053000, China. pengflyl@163.com.

Funding

Hebei Provincial Health Commission of China 20232182
6 · The paper itself

Abstract

backgroundUmbilical venous catheterization (UVC) is commonly performed in neonates, but improper catheter tip may lead to hepatic complications.

aimThis study aims to retrospectively analyze the relationship between UVC tip position and the occurrence of hepatic complications, utilizing ultrasound for early detection and characterization of hepatic injury.

methodsWe conducted a retrospective study of 206 preterm neonates who underwent UVC insertion in a NICU from January 2021 to December 2023. All patients with complete post‒UVC insertion abdominal ultrasound follow‒up records were included. According to the UVC tip position, neonates were divided into two groups: the Central Group and the Non-central Group. Within the non-central group, cases with the tip located in the ductus venosus (DV) formed the DV Subgroup. The incidence of hepatic complications, including portal venous gas, portal vein thrombosis, and hepatic parenchymal injury, was compared across these groups.

resultsHepatic complications were observed in 23 neonates (11.2%, 23/206), including portal venous gas (6.3%), portal vein thrombosis (1.9%), and hepatic parenchymal injury (2.9%). Among these, 9 cases (39.1%) occurred in the Central Group, while 14 cases (60.9%) were in the Non-Central Group, with 8 of these (57.1%) belonging to the DV Subgroup. The Non-Central Group accounted for the majority of complications, including all cases of hepatic parenchymal injury, with a proportion involving the DV Subgroup. These findings suggest an elevated risk of complications associated with non-central catheter tip position.

conclusionNon-central catheter tip positions increase the risk of hepatic complications. Regular ultrasound follow-up is crucial for ensuring proper tip position and early complication detection.

Indexed as

Catheterization, PeripheralLiverLiver DiseasesUmbilical VeinsFemaleHumansInfant, NewbornInfant, PrematureMaleRetrospective StudiesUltrasonographyCatheter tip positionHepatic injuryNeonatal carePortal vein thrombosisUltrasoundUmbilical venous catheter

Identifiers

PMID40097960
PMCPMC11912731

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.