Evidence map›Paper›PMID 40096466›Full record

ArticleSensors (Basel, Switzerland)2025

Mechanical Structure Design and Motion Simulation Analysis of a Lower Limb Exoskeleton Rehabilitation Robot Based on Human-Machine Integration.

Chenglong Zhao, Zhen Liu, Yuefa Ou, Liucun Zhu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Chenglong ZhaoGuangxi Key Laboratory of Ocean Engineering Equipment and Technology, Beibu Gulf University, Qinzhou 535011, China.
Zhen LiuDepartment of Integrated Systems Engineering, Nagasaki Institute of Applied Science, Nagasaki 851-0193, Japan.
Yuefa OuGuangxi Key Laboratory of Ocean Engineering Equipment and Technology, Beibu Gulf University, Qinzhou 535011, China.
Liucun ZhuAdvanced Science and Technology Research Institute, Beibu Gulf University, Qinzhou 535001, China.

Funding

2024 Guangxi Universities Enhancement of Research Capability for Young and Middle-aged Teachers Project No. 2024KY0447
6 · The paper itself

Abstract

Population aging is an inevitable trend in contemporary society, and the application of technologies such as human-machine interaction, assistive healthcare, and robotics in daily service sectors continues to increase. The lower limb exoskeleton rehabilitation robot has great potential in areas such as enhancing human physical functions, rehabilitation training, and assisting the elderly and disabled. This paper integrates the structural characteristics of the human lower limb, motion mechanics, and gait features to design a biomimetic exoskeleton structure and proposes a human-machine integrated lower limb exoskeleton rehabilitation robot. Human gait data are collected using the Optitrack optical 3D motion capture system. SolidWorks 3D modeling software Version 2021 is used to create a virtual prototype of the exoskeleton, and kinematic analysis is performed using the standard Denavit-Hartenberg (D-H) parameter method. Kinematic simulations are carried out using the Matlab Robotic Toolbox Version R2018a with the derived D-H parameters. A physical prototype was fabricated and tested to verify the validity of the structural design and gait parameters. A controller based on BP fuzzy neural network PID control is designed to ensure the stability of human walking. By comparing two sets of simulation results, it is shown that the BP fuzzy neural network PID control outperforms the other two control methods in terms of overshoot and settling time. The specific conclusions are as follows: after multiple walking gait tests, the robot's walking process proved to be relatively safe and stable; when using BP fuzzy neural network PID control, there is no significant oscillation, with an overshoot of 5.5% and a settling time of 0.49 s, but the speed was slow, with a walking speed of approximately 0.18 m/s, a stride length of about 32 cm, and a gait cycle duration of approximately 1.8 s. The model proposed in this paper can effectively assist patients in recovering their ability to walk. However, the lower limb exoskeleton rehabilitation robot still faces challenges, such as a slow speed, large size, and heavy weight, which need to be optimized and improved in future research.

Indexed as

Exoskeleton DeviceLower ExtremityRoboticsBiomechanical PhenomenaComputer SimulationEquipment DesignFuzzy LogicGaitHumansMan-Machine SystemsMotionNeural Networks, ComputerRehabilitationWalkingkinematic simulationlower limb exoskeletonrehabilitation robotstructural design