ArticleSensors (Basel, Switzerland)2025
A Sensor Employing an Array of Silicon Photomultipliers for Detection of keV Ions in Time-of-Flight Mass Spectrometry.
Antonio Mariscal-Castilla, Markus Piller, Jerome Alozy, Rafael Ballabriga, Michael Campbell, Oscar de la Torre, David Gascón, Sergio Gómez, David Heathcote, Joan Mauricio and 4 more
Abstract read
In one paragraphArticle in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from itWhat it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
2 · The registryThe trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
3 · Its place in the literatureWho cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
4 · The recordCorrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
5 · Who and what moneyAuthors and funding
14 authors.
Antonio Mariscal-CastillaDepartment of Física Quàntica i Astrofísica, Institut de Ciències Del Cosmos, Universidad de Barcelona, 08007 Barcelona, Spain.
Markus PillerDepartment of Microelectronics, Cern, Esplanade des Particules 1, 1211 Meyrin, Switzerland.ORCID 0000-0002-1408-2962 Jerome AlozyDepartment of Microelectronics, Cern, Esplanade des Particules 1, 1211 Meyrin, Switzerland.
Rafael BallabrigaDepartment of Microelectronics, Cern, Esplanade des Particules 1, 1211 Meyrin, Switzerland.
Michael CampbellDepartment of Microelectronics, Cern, Esplanade des Particules 1, 1211 Meyrin, Switzerland.
Oscar de la TorreDepartment of Física Quàntica i Astrofísica, Institut de Ciències Del Cosmos, Universidad de Barcelona, 08007 Barcelona, Spain.
David GascónDepartment of Física Quàntica i Astrofísica, Institut de Ciències Del Cosmos, Universidad de Barcelona, 08007 Barcelona, Spain.
Sergio GómezSerra Hunter Fellow, Department of Enginyeria Electrònica, Universitat Politècnica de Catalunya, 08034 Barcelona, Spain.
David HeathcoteChemistry Research Laboratory, Department of Chemistry, University of Oxford, Oxford OX1 3TA, UK.ORCID 0000-0003-0611-8555 Joan MauricioDepartment of Física Quàntica i Astrofísica, Institut de Ciències Del Cosmos, Universidad de Barcelona, 08007 Barcelona, Spain.ORCID 0000-0002-9331-1363 Dennis MilesevicChemistry Research Laboratory, Department of Chemistry, University of Oxford, Oxford OX1 3TA, UK.ORCID 0000-0003-4909-5293 Andreu SanuyDepartment of Física Quàntica i Astrofísica, Institut de Ciències Del Cosmos, Universidad de Barcelona, 08007 Barcelona, Spain.ORCID 0000-0002-5767-3623 Claire VallanceChemistry Research Laboratory, Department of Chemistry, University of Oxford, Oxford OX1 3TA, UK.
Daniel GubermanDepartment of Física Quàntica i Astrofísica, Institut de Ciències Del Cosmos, Universidad de Barcelona, 08007 Barcelona, Spain.ORCID 0000-0002-9636-1825 Funding
Engineering and Physical Sciences Research Council EP/T021675/1Engineering and Physical Sciences Research Council EP/V026690/1MCIN/AEI/ 10.13039/501100011033, "ERDF A way of 332 making Europe" PDC2021-121442-10MICIIN with funding from European Union 334 NextGenerationEU(PRTR-C17.I1) and by Generalitat de Catalunya. PRTR-C17.I1Spanish Government through the European 336 Union NextGenerationEU fund. Maria Zambrano Grant
6 · The paper itselfAbstract
Pixellated scintillation detectors have the potential to overcome several limitations of conventional microchannel-plate-based detectors employed in time-of-flight mass spectrometry (ToF-MS), such as extending detector lifetime, reducing vacuum requirements, or increasing the ion throughput. We have developed a prototype comprising a fast organic scintillator (Exalite 404) coupled to an array of 16 silicon photomultipliers (SiPMs), with read-out electronics based on the FastIC application-specific integrated circuit (ASIC). Each SiPM signal processed by FastIC is fed into its own time-to-digital converter (TDC). The dead time of a single channel can be as short as ∼20 ns. As a result, our system have the potential to process ion rates above 109 cm
Indexed as
ASICsion detectorsilicon photomultiplierSiPMtime-of-flight mass spectrometryvelocity-map imaging
Identifiers
PMID40096465
PMCPMC11902436
What OpenQuestion holds
Textmetadata
LicenceCC BY
Read underepoch 390